Rotational Projection Errors in Coronal Knee Alignment on Weight-Bearing Whole-Leg Radiographs: A 3D CT Reference Across CPAK Morphotypes

Igor Strahovnik, Andrej Strahovnik iD, Samo Karel Fokter iD

Bioengineering · 23.07.2025 · 12 (8) · 794

DOI: 10.3390/bioengineering12080794 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 23.07.2025. Verfasst von Igor Strahovnik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Whole-leg radiographs (WLRs) are widely used to assess coronal alignment before total knee arthroplasty (TKA), but may be inaccurate in patients with atypical morphotypes or malrotation. This study evaluated the discrepancy between WLR and 3D computed tomography (CT) scans across coronal plane alignment of the knee (CPAK) morphotypes and introduced a novel projection index—the femoral notch projection ratio (FNPR). In CPAK III knees, 19% of cases exceeded a clinically relevant threshold (>3° difference), prompting investigation of underlying projection factors. In 187 knees, coronal angles—including the medial distal femoral angle (MDFA°), medial proximal tibial angle (MPTA°), femoral mechanical angle (FMA°), and arithmetic hip–knee–ankle angle (aHKA°)—were measured using WLR and CT. Rotational positioning on WLR was assessed using FNPR and the patellar projection ratio (PPR). CPAK classification was applied. WLR systematically underestimated alignment, with the greatest bias in CPAK III (MDFA° + 1.5° ± 2.0°, p < 0.001). FNPR was significantly higher in CPAK III and VI (+1.9° vs. −0.3°, p < 0.001), indicating a tendency toward internally rotated limb positioning during imaging. The PPR–FNPR mismatch peaked in CPAK III (4.1°, p < 0.001), suggesting patellar-based centering may mask rotational malprojection. Projection artifacts from anterior osteophytes contributed to outlier measurements but were correctable. Valgus morphotypes with oblique joint lines (CPAK III) were especially prone to projection error. FNPR more accurately reflected rotational malposition than PPR in morphotypes prone to patellar subluxation. A 3D method (e.g., CT) or repeated imaging may be considered in CPAK III to improve surgical planning.

Schlagwörter

Stichwörter der Autor:innen

3D CTCPAK classificationMDFAcoronal alignmentfemoral notch projection ratio (FNPR) indexprojection-based alignment indexsystematic projection errortotal knee arthroplastyweight-bearing radiographs

Autor:innen und Institutionen

  • Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia.
  • Valdoltra Orthopeadic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia.
  • University Medical Center Maribor, Ljubljanska ulica 5, 2000 Maribor, Slovenia.
  • Faculty of Medicine, University of Maribor, Slomškov trg 15, 2000 Maribor, Slovenia.

ORCID-Profile: Andrej Strahovnik, Samo Karel Fokter

Zitieren

APA

Strahovnik, I., Strahovnik, A., & Fokter, S. K. (2025). Rotational Projection Errors in Coronal Knee Alignment on Weight-Bearing Whole-Leg Radiographs: A 3D CT Reference Across CPAK Morphotypes. Bioengineering, 12(8), 794. https://doi.org/10.3390/bioengineering12080794

Vancouver

Strahovnik I, Strahovnik A, Fokter SK. Rotational Projection Errors in Coronal Knee Alignment on Weight-Bearing Whole-Leg Radiographs: A 3D CT Reference Across CPAK Morphotypes. Bioengineering. 2025;12(8):794. doi:10.3390/bioengineering12080794

BibTeX
@article{Strahovnik2025,
  author = {Strahovnik, Igor and Strahovnik, Andrej and Fokter, Samo Karel},
  title = {Rotational Projection Errors in Coronal Knee Alignment on Weight-Bearing Whole-Leg Radiographs: A 3D CT Reference Across CPAK Morphotypes},
  journal = {Bioengineering},
  year = {2025},
  volume = {12},
  number = {8},
  pages = {794},
  doi = {10.3390/bioengineering12080794}
}
Kostenlos starten →