EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Creating Blood Analogs to Mimic Steady-State Non-Newtonian Shear-Thinning Characteristics Under Various Thermal Conditions

Hang Yi iD, Alexander Wang, Christopher Wang, Jared Chong iD, Chungyiu Ma, Luke Bramlage, Bryan Ludwig, Zifeng Yang iD

Bioengineering · 12.07.2025 · 12 (7) · 758

DOI: 10.3390/bioengineering12070758 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 12.07.2025. Verfasst von Hang Yi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Materials Engineering, Wright State University, 3640 Colonel Glenn Hwy., Dayton, OH 45435, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Premier Health and Boonshoft School of Medicine Endowment Funding at Wright State University, Boonshoft School of Medicine Seed Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blood analogs are widely employed in in vitro experiments such as particle image velocity (PIV) to secure hemodynamics, assisting pathophysiological diagnoses of neurovascular and cardiovascular diseases, as well as pre-surgical planning and intraoperative orientation. To obtain accurate physical parameters, which are critical for diagnosis and treatment, blood analogs should exhibit realistic non-Newtonian shear-thinning features. In this study, two types of blood analogs working under room temperature (293.15 K) were created to mimic the steady-state shear-thinning features of blood over a temperature range of 295 to 312 K and a shear range of 1~250 s−1 at a hematocrit of ~40%. Type I was a general-purpose analog composed of deionized (DI) water and xanthan gum (XG) powder, while Type II was specially designed for PIV tests, incorporating DI water, XG, and fluorescent microspheres. By minimizing the root mean square deviation between generated blood analogs and an established viscosity model, formulas for both blood analogs were successfully derived for the designated temperatures. The results showed that both blood analogs could replicate the shear-thinning viscosities of real blood, with the averaged relative discrepancy < 5%. Additionally, a strong linear correlation was observed between body temperature and XG concentration in both blood analogs (coefficient of determination > 0.96): for Type I, 295–312 K correlates with 140–520 ppm, and for Type II, 295–315 K correlates with 200–560 ppm. This work bridges the gap between idealized steady-state non-Newtonian viscosity models of blood and the complexities of real-world physiological conditions, offering a versatile platform for advancing particle image velocimetry tests and hemodynamics modeling, optimizing therapeutic interventions, and enhancing biomedical technologies in temperature-sensitive environments.

Schlagwörter

Stichwörter der Autor:innen

blood analognon-Newtonianshear-thinningsteady-statetemperature

Autor:innen und Institutionen

  • Department of Mechanical and Materials Engineering, Wright State University, 3640 Colonel Glenn Hwy., Dayton, OH 45435, USA.
  • Centerville High School, 500 E Franklin St, Centerville, OH 45459, USA.
  • St. Andrew's College, Aurora, ON L4G 3H7, Canada.
  • Clinical Neuroscience Institute, Premier Health-Miami Valley Hospital, Dayton, OH 45409, USA.
  • Boonshoft School of Medicine, Wright State University, 3640 Colonel Glenn Hwy., Dayton, OH 45435, USA.

ORCID-Profile: Hang Yi, Jared Chong, Zifeng Yang

Förderung

  • Premier Health and Boonshoft School of Medicine Endowment Funding at Wright State University
  • Boonshoft School of Medicine Seed Fund

Zitieren

APA

Yi, H., Wang, A., Wang, C., Chong, J., Ma, C., Bramlage, L., Ludwig, B., & Yang, Z. (2025). Creating Blood Analogs to Mimic Steady-State Non-Newtonian Shear-Thinning Characteristics Under Various Thermal Conditions. Bioengineering, 12(7), 758. https://doi.org/10.3390/bioengineering12070758

Vancouver

Yi H, Wang A, Wang C, Chong J, Ma C, Bramlage L, et al. Creating Blood Analogs to Mimic Steady-State Non-Newtonian Shear-Thinning Characteristics Under Various Thermal Conditions. Bioengineering. 2025;12(7):758. doi:10.3390/bioengineering12070758

BibTeX
@article{Yi2025,
  author = {Yi, Hang and Wang, Alexander and Wang, Christopher and Chong, Jared and Ma, Chungyiu and Bramlage, Luke and Ludwig, Bryan and Yang, Zifeng},
  title = {Creating Blood Analogs to Mimic Steady-State Non-Newtonian Shear-Thinning Characteristics Under Various Thermal Conditions},
  journal = {Bioengineering},
  year = {2025},
  volume = {12},
  number = {7},
  pages = {758},
  doi = {10.3390/bioengineering12070758}
}
Kostenlos starten →