Fachartikel in der Zeitschrift Bioengineering, online erschienen am 06.06.2025. Verfasst von Sijuan Huang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Sun Yat-sen University Cancer Center, Guangzhou 510060, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Beijing Xisike Clinical Oncology Research Foundation, United Laboratory of Frontier Radiotherapy Technology Fund.
Abstract (Originalsprache)
Objective
The objective of this study was to develop and assess the clinical feasibility of auto-segmentation and auto-planning methodologies for automated radiotherapy in prostate cancer.
Methods
A total of 166 patients were used to train a 3D Unet model for segmentation of the gross tumor volume (GTV), clinical tumor volume (CTV), nodal CTV (CTVnd), and organs at risk (OARs). Performance was assessed by the Dice similarity coefficient (DSC), the Recall, Precision, Volume Ratio (VR), the 95% Hausdorff distance (HD95%), and the volumetric revision degree (VRD). An auto-planning network based on a 3D Unet was trained on 77 treatment plans derived from the 166 patients. Dosimetric differences and clinical acceptability of the auto-plans were studied. The effect of OAR editing on dosimetry was also evaluated.
Results
On an independent set of 50 cases, the auto-segmentation process took 1 min 20 s per case. The DSCs for GTV, CTV, and CTVnd were 0.87, 0.88, and 0.82, respectively, with VRDs ranging from 0.09 to 0.14. The segmentation of OARs demonstrated high accuracy (DSC ≥ 0.83, Recall/Precision ≈ 1.0). The auto-planning process required 1–3 optimization iterations for 50%, 40%, and 10% of cases, respectively, and exhibited significant better conformity (p ≤ 0.01) and OAR sparing (p ≤ 0.03) while maintaining comparable target coverage. Only 6.7% of auto-plans were deemed unacceptable compared to 20% of manual plans, with 75% of auto-plans considered superior. Notably, the editing of OARs had no significant impact on doses.
Conclusions
The accuracy of auto-segmentation is comparable to that of manual segmentation, and the auto-planning offers equivalent or better OAR protection, meeting the requirements of online automated radiotherapy and facilitating its clinical application.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sun Yat-sen University Cancer Center, Guangzhou 510060, China.
- United Laboratory of Frontier Radiotherapy Technology of Sun Yat-sen University & Chinese Academy of Sciences Ion Medical Technology Co., Ltd., Guangzhou 510060, China.
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
- Department of Radiation Oncology, Sun Yat-sen Memorial Hospital, Guangzhou 510012, China.
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai 201807, China.
ORCID-Profile: Li Chen, Xiaoyan Huang
Förderung
- National Key Research and Development Program of China
- Beijing Xisike Clinical Oncology Research Foundation
- United Laboratory of Frontier Radiotherapy Technology Fund
Zitieren
APA
Huang, S., Wu, J., Lin, X., Wang, G., Song, T., Chen, L., Jia, L., Cao, Q., Liu, R., Liu, Y., Yang, X., Huang, X., & He, L. (2025). Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer. Bioengineering, 12(6), 620. https://doi.org/10.3390/bioengineering12060620
Vancouver
Huang S, Wu J, Lin X, Wang G, Song T, Chen L, et al. Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer. Bioengineering. 2025;12(6):620. doi:10.3390/bioengineering12060620
BibTeX
@article{Huang2025,
author = {Huang, Sijuan and Wu, Jingheng and Lin, Xi and Wang, Guangyu and Song, Ting and Chen, Li and Jia, Lecheng and Cao, Qian and Liu, Ruiqi and Liu, Yang and Yang, Xin and Huang, Xiaoyan and He, Liru},
title = {Auto-Segmentation and Auto-Planning in Automated Radiotherapy for Prostate Cancer},
journal = {Bioengineering},
year = {2025},
volume = {12},
number = {6},
pages = {620},
doi = {10.3390/bioengineering12060620}
}
EUVIMED