EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Critical Design Considerations for Longer-Term Wear and Comfort of On-Body Medical Devices

Shavini Stuart, Margreet de Kok, Ben O'Searcoid, Hannah Morrisroe, Irina Bianca Serban, Ferry Jagers, Remon Dulos, Steven Houben iD, Linda van de Peppel, Jeroen van den Brand

Bioengineering · 24.10.2024 · 11 (11) · 1058

DOI: 10.3390/bioengineering11111058 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 24.10.2024. Verfasst von Shavini Stuart und 9 weiteren Autor:innen. Beteiligte Einrichtung: TNO, Holst Centre, High Tech Campus 31, 5656AE Eindhoven, The Netherlands. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ITEA, ITEA INNO4HEALTH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The commercialization of a growing number of wearable devices has been enabled within recent years due to the availability of miniaturized sensor modalities, the development of new materials, and the scalability of flexible electronics. With the increase in resource shortages within healthcare, there is a demand to translate wearable devices from the commercial consumer stand-point to the medical field. Clinical-grade signal quality, wearability, and comfort all need to be tailored to a wearable design. Wear and comfort for user compliance and durability for longer-term use are commonly overlooked. In this study, the relationship of on-body location and material layer composition is investigated. Five non-woven medical tapes noted for longer wear time are tested over a 7-day timeframe. The impact of material properties, such as elasticity, isotropy, and hysteresis, as well as the moisture vapor transmission rate (MVTR) and adhesive thickness, are evaluated in relation to skin properties on the lower torso of 30, high-activity-level volunteers. User perception was quantified via Likert-scale questionnaires and images were obtained for the material–skin interaction. The results indicate that critical characteristics, such as MVTR and elasticity, noted for positive skin interaction in commercial products, may not translate to improved user perception and durability over time. Future work will assess new design options to manipulate material properties for improved wear and comfort.

Schlagwörter

Stichwörter der Autor:innen

MVTRhigher activitynon-woven tapesskin-based wearable devicesuser perceptionwear and comfort

Autor:innen und Institutionen

  • TNO, Holst Centre, High Tech Campus 31, 5656AE Eindhoven, The Netherlands.
  • Industrial Design and Artificial Intelligence Systems Institute, Eindhoven University of Technology, 5612AZ Eindhoven, The Netherlands.
  • TNO, Healthy Living, Sylviusweg 71, 2333BE Leiden, The Netherlands.

ORCID-Profile: Steven Houben

Förderung

  • ITEA
  • ITEA INNO4HEALTH

Zitieren

APA

Stuart, S., de Kok, M., O'Searcoid, B., Morrisroe, H., Serban, I. B., Jagers, F., Dulos, R., Houben, S., van de Peppel, L., & van den Brand, J. (2024). Critical Design Considerations for Longer-Term Wear and Comfort of On-Body Medical Devices. Bioengineering, 11(11), 1058. https://doi.org/10.3390/bioengineering11111058

Vancouver

Stuart S, de Kok M, O'Searcoid B, Morrisroe H, Serban IB, Jagers F, et al. Critical Design Considerations for Longer-Term Wear and Comfort of On-Body Medical Devices. Bioengineering. 2024;11(11):1058. doi:10.3390/bioengineering11111058

BibTeX
@article{Stuart2024,
  author = {Stuart, Shavini and de Kok, Margreet and O'Searcoid, Ben and Morrisroe, Hannah and Serban, Irina Bianca and Jagers, Ferry and Dulos, Remon and Houben, Steven and van de Peppel, Linda and van den Brand, Jeroen},
  title = {Critical Design Considerations for Longer-Term Wear and Comfort of On-Body Medical Devices},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {11},
  pages = {1058},
  doi = {10.3390/bioengineering11111058}
}