EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Augmented Reality-Guided Extraction of Fully Impacted Lower Third Molars Based on Maxillofacial CBCT Scans

Marcus Rieder iD, Bernhard Remschmidt iD, Christina Gsaxner iD, Jan Gaessler, Michael Payer, Wolfgang Zemann, Juergen Wallner iD

Bioengineering · 18.06.2024 · 11 (6) · 625

DOI: 10.3390/bioengineering11060625 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 18.06.2024. Verfasst von Marcus Rieder und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Oral and Maxillofacial Surgery, Department of Dental Medicine and Oral Health, Medical University of Graz, 8036 Graz, Austria. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund, Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

This study aimed to integrate an augmented reality (AR) image-guided surgery (IGS) system, based on preoperative cone beam computed tomography (CBCT) scans, into clinical practice. (2)

Methods

In preclinical and clinical surgical setups, an AR-guided visualization system based on Microsoft’s HoloLens 2 was assessed for complex lower third molar (LTM) extractions. In this study, the system’s potential intraoperative feasibility and usability is described first. Preparation and operating times for each procedure were measured, as well as the system’s usability, using the System Usability Scale (SUS). (3)

Results

A total of six LTMs (n = 6) were analyzed, two extracted from human cadaver head specimens (n = 2) and four from clinical patients (n = 4). The average preparation time was 166 ± 44 s, while the operation time averaged 21 ± 5.9 min. The overall mean SUS score was 79.1 ± 9.3. When analyzed separately, the usability score categorized the AR-guidance system as “good” in clinical patients and “best imaginable” in human cadaver head procedures. (4)

Conclusions

This translational study analyzed the first successful and functionally stable application of the HoloLens technology for complex LTM extraction in clinical patients. Further research is needed to refine the technology’s integration into clinical practice to improve patient outcomes.

Schlagwörter

Stichwörter der Autor:innen

augmented realitycomputer-assistedcone beam computed tomographymolaroral surgical proceduresurgerythirdtooth extraction

Autor:innen und Institutionen

  • Division of Oral and Maxillofacial Surgery, Department of Dental Medicine and Oral Health, Medical University of Graz, 8036 Graz, Austria.
  • Institute of Computer Graphics and Vision, Graz University of Technology, 8010 Graz, Austria.
  • Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria.

ORCID-Profile: Marcus Rieder, Bernhard Remschmidt, Christina Gsaxner, Juergen Wallner

Förderung

  • Austrian Science Fund
  • Medical University

Zitieren

APA

Rieder, M., Remschmidt, B., Gsaxner, C., Gaessler, J., Payer, M., Zemann, W., & Wallner, J. (2024). Augmented Reality-Guided Extraction of Fully Impacted Lower Third Molars Based on Maxillofacial CBCT Scans. Bioengineering, 11(6), 625. https://doi.org/10.3390/bioengineering11060625

Vancouver

Rieder M, Remschmidt B, Gsaxner C, Gaessler J, Payer M, Zemann W, et al. Augmented Reality-Guided Extraction of Fully Impacted Lower Third Molars Based on Maxillofacial CBCT Scans. Bioengineering. 2024;11(6):625. doi:10.3390/bioengineering11060625

BibTeX
@article{Rieder2024,
  author = {Rieder, Marcus and Remschmidt, Bernhard and Gsaxner, Christina and Gaessler, Jan and Payer, Michael and Zemann, Wolfgang and Wallner, Juergen},
  title = {Augmented Reality-Guided Extraction of Fully Impacted Lower Third Molars Based on Maxillofacial CBCT Scans},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {6},
  pages = {625},
  doi = {10.3390/bioengineering11060625}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche