Fachartikel in der Zeitschrift Bioengineering, online erschienen am 15.06.2024. Verfasst von Fei Tan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Imaging, Diagnostics and Software Reliability (DIDSR), Office of Science and Engineering Laboratories (OSEL), Center for Devices and Radi…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Oak Ridge Institute for Science and Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

Schlagwörter

Stichwörter der Autor:innen

MRI reconstructionautomated image quality evaluationdigital image quality phantomdigital reference objectimage resolutionlow-contrast detectabilitymachine learning

Autor:innen und Institutionen

  • Division of Imaging, Diagnostics and Software Reliability (DIDSR), Office of Science and Engineering Laboratories (OSEL), Center for Devices and Radiological Health (CDRH), U.S. Food and Drug Administration (U.S. FDA),…

ORCID-Profile: Fei Tan, Jana G Delfino, Rongping Zeng

Förderung

  • Oak Ridge Institute for Science and Education

Zitieren

APA

Tan, F., Delfino, J. G., & Zeng, R. (2024). Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms. Bioengineering, 11(6), 614. https://doi.org/10.3390/bioengineering11060614

Vancouver

Tan F, Delfino JG, Zeng R. Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms. Bioengineering. 2024;11(6):614. doi:10.3390/bioengineering11060614

BibTeX
@article{Tan2024,
  author = {Tan, Fei and Delfino, Jana G and Zeng, Rongping},
  title = {Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {6},
  pages = {614},
  doi = {10.3390/bioengineering11060614}
}
Kostenlos starten →