Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 03.06.2024. Verfasst von Anmar Salih und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The human heart’s remarkable vitality necessitates a deep understanding of its mechanics, particularly concerning cardiac device leads. This paper presents advancements in finite element modeling for cardiac leads and 3D heart models, leveraging computational simulations to assess lead behavior over time. Through detailed modeling and meshing techniques, we accurately captured the complex interactions between leads and heart tissue. Material properties were assigned based on ASTM (American Society for Testing and Materials) standards and in vivo exposure data, ensuring realistic simulations. Our results demonstrate close agreement between experimental and simulated data for silicone insulation in pacemaker leads, with a mean force tolerance of 19.6 N ± 3.6 N, an ultimate tensile strength (UTS) of 6.3 MPa ± 1.15 MPa, and a percentage elongation of 125% ± 18.8%, highlighting the effectiveness of simulation in predicting lead performance. Similarly, for polyurethane insulation in ICD leads, we found a mean force of 65.87 N ± 7.1 N, a UTS of 10.7 MPa ± 1.15 MPa, and a percentage elongation of 259.3% ± 21.4%. Additionally, for polyurethane insulation in CRT leads, we observed a mean force of 53.3 N ± 2.06 N, a UTS of 22.11 MPa ± 0.85 MPa, and a percentage elongation of 251.6% ± 13.2%. Correlation analysis revealed strong relationships between mechanical properties, further validating the simulation models. Classification models constructed using both experimental and simulated data exhibited high discriminative ability, underscoring the reliability of simulation in analyzing lead behavior. These findings contribute to the ongoing efforts to improve cardiac device lead design and optimize patient outcomes.

Schlagwörter

Stichwörter der Autor:innen

CIED leads insulationCRT leadsICD leadscardiac device leadscomputational simulationsfinite element modelingin vivo environmentlead behaviorpacemaker leadspolyurethane insulationsilicone insulation

Autor:innen und Institutionen

  • Department of Biomedical, Industrial and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA.
  • Department of Orthopedic Surgery, Sports Medicine and Rehabilitation, Miami Valley Hospital, Dayton, OH 45409, USA.

ORCID-Profile: Anmar Salih, Farah Hamandi, Tarun Goswami

Zitieren

APA

Salih, A., Hamandi, F., & Goswami, T. (2024). Advancements in Finite Element Modeling for Cardiac Device Leads and 3D Heart Models. Bioengineering, 11(6), 564. https://doi.org/10.3390/bioengineering11060564

Vancouver

Salih A, Hamandi F, Goswami T. Advancements in Finite Element Modeling for Cardiac Device Leads and 3D Heart Models. Bioengineering. 2024;11(6):564. doi:10.3390/bioengineering11060564

BibTeX
@article{Salih2024,
  author = {Salih, Anmar and Hamandi, Farah and Goswami, Tarun},
  title = {Advancements in Finite Element Modeling for Cardiac Device Leads and 3D Heart Models},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {6},
  pages = {564},
  doi = {10.3390/bioengineering11060564}
}
Kostenlos starten →