Comparative Analysis of Plaque Removal and Wear between Electric–Mechanical and Bioelectric Toothbrushes
Bioengineering · 09.05.2024 · 11 (5) · 474
DOI: 10.3390/bioengineering11050474 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 09.05.2024. Verfasst von Jihyun Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology, Ulsan University Hospital, College of Medicine, University of Ulsan, 877 Bangeojinsunhwando-ro, Dong-gu, Ulsan 44033, R…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Ministry of SMEs and Startups in Korea, Technology Development Program, Ministry of SMEs and Startups (MSS, Republic of Korea).
Abstract (Originalsprache)
Effective oral care is important for maintaining a high quality of life. Therefore, plaque control can prevent the development and recurrence of periodontitis. Brushing with a toothbrush and toothpaste is a common way to remove plaque; however, excessive brushing or brushing with abrasive toothpaste can cause wear and tear on the dental crown. Hence, we aimed to quantitatively compare the plaque-removal efficiency and tooth wear of toothbrushes using the bioelectric effect (BE) with those of electric–mechanical toothbrushes. To generate the BE signal, an electronic circuit was developed and embedded in a toothbrush. Further, typodonts were coated with cultured artificial plaques and placed in a brushing simulator. A toothpaste slurry was applied, and the typodonts were eluted with tap water after brushing. The plaques of the typodonts were captured, and the images were quantified. For the tooth wear experiment, polymethyl methacrylate disk resin blocks were brushed twice a day, and the thickness of the samples was measured. Subsequently, statistical differences between the experimental toothbrushes and typical toothbrushes were analyzed. The BE toothbrush had a higher plaque-removal efficiency and could minimize tooth wear. This study suggests that the application of BE may be a new solution for oral care.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Periodontology, Ulsan University Hospital, College of Medicine, University of Ulsan, 877 Bangeojinsunhwando-ro, Dong-gu, Ulsan 44033, Republic of Korea.
- PAIST (ProxiHealthcare Institute for Science and Technology), ProxiHealthcare Inc., Seoul 08507, Republic of Korea.
ORCID-Profile: Jihyun Lee, Young Wook Kim
Förderung
- the Ministry of SMEs and Startups in Korea
- Technology Development Program
- Ministry of SMEs and Startups (MSS, Republic of Korea)
Zitieren
APA
Lee, J., Park, H. M., & Kim, Y. W. (2024). Comparative Analysis of Plaque Removal and Wear between Electric–Mechanical and Bioelectric Toothbrushes. Bioengineering, 11(5), 474. https://doi.org/10.3390/bioengineering11050474
Vancouver
Lee J, Park HM, Kim YW. Comparative Analysis of Plaque Removal and Wear between Electric–Mechanical and Bioelectric Toothbrushes. Bioengineering. 2024;11(5):474. doi:10.3390/bioengineering11050474
BibTeX
@article{Lee2024,
author = {Lee, Jihyun and Park, Hyun M and Kim, Young Wook},
title = {Comparative Analysis of Plaque Removal and Wear between Electric–Mechanical and Bioelectric Toothbrushes},
journal = {Bioengineering},
year = {2024},
volume = {11},
number = {5},
pages = {474},
doi = {10.3390/bioengineering11050474}
}
EUVIMED