Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants
Bioengineering · 19.04.2024 · 11 (4) · 395
DOI: 10.3390/bioengineering11040395 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 19.04.2024. Verfasst von Massimiliano Baleani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero della Salute, Italian Ministry of Health.
Abstract (Originalsprache)
The literature suggests that the yield strain of cortical bone is invariant to its stiffness (elastic modulus) and strength (yield stress). However, data about intra-individual variations, e.g., the influence of different collagen/mineral organisations observed in bone aspects withstanding different habitual loads, are lacking. The hypothesis that the yield strain of human cortical bone tissue, retrieved from femoral diaphyseal quadrants subjected to different habitual loads, is invariant was tested. Four flat dumbbell-shaped specimens were machined from each quadrant of the proximal femoral diaphysis of five adult donors for a total of 80 specimens. Two extensometers attached to the narrow specimen region were used to measure deformation during monotonic tensile testing. The elastic modulus (linear part of the stress–strain curve) and yield strain/stress at a 0.2% offset were obtained. Elastic modulus and yield stress values were, respectively, in the range of 12.2–20.5 GPa and 75.9–136.6 MPa and exhibited a positive linear correlation. All yield strain values were in the narrow range of 0.77–0.87%, regardless of the stiffness and strength of the tissue and the anatomical quadrant. In summary, the results corroborate the hypothesis that tensile yield strain in cortical bone is invariant, irrespective also of the anatomical quadrant. The mean yield strain value found in this study is similar to what was reported by inter-species and evolution studies but slightly higher than previous reports in humans, possibly because of the younger age of our subjects. Further investigations are needed to elucidate a possible dependence of yield strain on age.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
- Laboratorio di Bioingegneria Computazionale, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
ORCID-Profile: Massimiliano Baleani, Paolo Erani
Förderung
- Ministero della Salute
- Italian Ministry of Health
Zitieren
APA
Baleani, M., Erani, P., Acciaioli, A., & Schileo, E. (2024). Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants. Bioengineering, 11(4), 395. https://doi.org/10.3390/bioengineering11040395
Vancouver
Baleani M, Erani P, Acciaioli A, Schileo E. Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants. Bioengineering. 2024;11(4):395. doi:10.3390/bioengineering11040395
BibTeX
@article{Baleani2024,
author = {Baleani, Massimiliano and Erani, Paolo and Acciaioli, Alice and Schileo, Enrico},
title = {Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants},
journal = {Bioengineering},
year = {2024},
volume = {11},
number = {4},
pages = {395},
doi = {10.3390/bioengineering11040395}
}
EUVIMED