Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images
Bioengineering · 27.02.2024 · 11 (3) · 227
DOI: 10.3390/bioengineering11030227 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 27.02.2024. Verfasst von Seong-Hyeon Kang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Eulji University, Seongnam 13135, Republic of Korea. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS, National Foundation of Korea.
Abstract (Originalsprache)
This study aimed to remove motion artifacts from brain magnetic resonance (MR) images using a U-Net model. In addition, a simulation method was proposed to increase the size of the dataset required to train the U-Net model while avoiding the overfitting problem. The volume data were rotated and translated with random intensity and frequency, in three dimensions, and were iterated as the number of slices in the volume data. Then, for every slice, a portion of the motion-free k-space data was replaced with motion k-space data, respectively. In addition, based on the transposed k-space data, we acquired MR images with motion artifacts and residual maps and constructed datasets. For a quantitative evaluation, the root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient of correlation (CC), and universal image quality index (UQI) were measured. The U-Net models for motion artifact reduction with the residual map-based dataset showed the best performance across all evaluation factors. In particular, the RMSE, PSNR, CC, and UQI improved by approximately 5.35×, 1.51×, 1.12×, and 1.01×, respectively, and the U-Net model with the residual map-based dataset was compared with the direct images. In conclusion, our simulation-based dataset demonstrates that U-Net models can be effectively trained for motion artifact reduction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Eulji University, Seongnam 13135, Republic of Korea.
- Department of Radiological Science, Gachon University, Incheon 21936, Republic of Korea.
Förderung
- NIA NIH HHS
- National Foundation of Korea
Zitieren
APA
Kang, S. H., & Lee, Y. (2024). Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images. Bioengineering, 11(3), 227. https://doi.org/10.3390/bioengineering11030227
Vancouver
Kang SH, Lee Y. Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images. Bioengineering. 2024;11(3):227. doi:10.3390/bioengineering11030227
BibTeX
@article{Kang2024,
author = {Kang, Seong-Hyeon and Lee, Youngjin},
title = {Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images},
journal = {Bioengineering},
year = {2024},
volume = {11},
number = {3},
pages = {227},
doi = {10.3390/bioengineering11030227}
}
EUVIMED