EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving Gait Analysis Techniques with Markerless Pose Estimation Based on Smartphone Location

Junhyuk Yang iD, Kiwon Park iD

Bioengineering · 30.01.2024 · 11 (2) · 141

DOI: 10.3390/bioengineering11020141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 30.01.2024. Verfasst von Junhyuk Yang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics Engineering, Incheon National University, Incheon 22012, Republic of Korea. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, National Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Marker-based 3D motion capture systems, widely used for gait analysis, are accurate but have disadvantages such as cost and accessibility. Whereas markerless pose estimation has emerged as a convenient and cost-effective alternative for gait analysis, challenges remain in achieving optimal accuracy. Given the limited research on the effects of camera location and orientation on data collection accuracy, this study investigates how camera placement affects gait assessment accuracy utilizing five smartphones. This study aimed to explore the differences in data collection accuracy between marker-based systems and pose estimation, as well as to assess the impact of camera location and orientation on accuracy in pose estimation. The results showed that the differences in joint angles between pose estimation and marker-based systems are below 5°, an acceptable level for gait analysis, with a strong correlation between the two datasets supporting the effectiveness of pose estimation in gait analysis. In addition, hip and knee angles were accurately measured at the front diagonal of the subject and ankle angle at the lateral side. This research highlights the significance of careful camera placement for reliable gait analysis using pose estimation, serving as a concise reference to guide future efforts in enhancing the quantitative accuracy of gait analysis.

Schlagwörter

Stichwörter der Autor:innen

gait analysishuman pose estimationkinematicslower extremitymarkerless

Autor:innen und Institutionen

  • Department of Mechatronics Engineering, Incheon National University, Incheon 22012, Republic of Korea.

ORCID-Profile: Junhyuk Yang, Kiwon Park

Förderung

  • Ministry of Science and ICT
  • National Research Foundation

Zitieren

APA

Yang, J., & Park, K. (2024). Improving Gait Analysis Techniques with Markerless Pose Estimation Based on Smartphone Location. Bioengineering, 11(2), 141. https://doi.org/10.3390/bioengineering11020141

Vancouver

Yang J, Park K. Improving Gait Analysis Techniques with Markerless Pose Estimation Based on Smartphone Location. Bioengineering. 2024;11(2):141. doi:10.3390/bioengineering11020141

BibTeX
@article{Yang2024,
  author = {Yang, Junhyuk and Park, Kiwon},
  title = {Improving Gait Analysis Techniques with Markerless Pose Estimation Based on Smartphone Location},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {2},
  pages = {141},
  doi = {10.3390/bioengineering11020141}
}