EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated Restarting Fast Proximal Gradient Descent Method for Single-View Cone-Beam X-ray Luminescence Computed Tomography Based on Depth Compensation

Peng Gao, Huangsheng Pu, Tianshuai Liu, Yilin Cao, Wangyang Li, Shien Huang, Ruijing Li, Hongbing Lu iD, Junyan Rong

Bioengineering · 26.01.2024 · 11 (2) · 123

DOI: 10.3390/bioengineering11020123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 26.01.2024. Verfasst von Peng Gao und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Single-view cone-beam X-ray luminescence computed tomography (CB-XLCT) has recently gained attention as a highly promising imaging technique that allows for the efficient and rapid three-dimensional visualization of nanophosphor (NP) distributions in small animals. However, the reconstruction performance is hindered by the ill-posed nature of the inverse problem and the effects of depth variation as only a single view is acquired. To tackle this issue, we present a methodology that integrates an automated restarting strategy with depth compensation to achieve reconstruction. The present study employs a fast proximal gradient descent (FPGD) method, incorporating L0 norm regularization, to achieve efficient reconstruction with accelerated convergence. The proposed approach offers the benefit of retrieving neighboring multitarget distributions without the need for CT priors. Additionally, the automated restarting strategy ensures reliable reconstructions without the need for manual intervention. Numerical simulations and physical phantom experiments were conducted using a custom CB-XLCT system to demonstrate the accuracy of the proposed method in resolving adjacent NPs. The results showed that this method had the lowest relative error compared to other few-view techniques. This study signifies a significant progression in the development of practical single-view CB-XLCT for high-resolution 3−D biomedical imaging.

Schlagwörter

Stichwörter der Autor:innen

X-ray luminescence computed tomographyill-posedimage reconstructionoptical tomography

Autor:innen und Institutionen

  • School of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
  • College of Advanced Interdisciplinary Studies & Hunan Provincial Key Laboratory of Novel NanoOptoelectronic Information Materials and Devices, National University of Defense Technology, Changsha 410073, China.
  • Nanhu Laser Laboratory, National University of Defense Technology, Changsha 410073, China.

ORCID-Profile: Hongbing Lu

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Gao, P., Pu, H., Liu, T., Cao, Y., Li, W., Huang, S., Li, R., Lu, H., & Rong, J. (2024). Automated Restarting Fast Proximal Gradient Descent Method for Single-View Cone-Beam X-ray Luminescence Computed Tomography Based on Depth Compensation. Bioengineering, 11(2), 123. https://doi.org/10.3390/bioengineering11020123

Vancouver

Gao P, Pu H, Liu T, Cao Y, Li W, Huang S, et al. Automated Restarting Fast Proximal Gradient Descent Method for Single-View Cone-Beam X-ray Luminescence Computed Tomography Based on Depth Compensation. Bioengineering. 2024;11(2):123. doi:10.3390/bioengineering11020123

BibTeX
@article{Gao2024,
  author = {Gao, Peng and Pu, Huangsheng and Liu, Tianshuai and Cao, Yilin and Li, Wangyang and Huang, Shien and Li, Ruijing and Lu, Hongbing and Rong, Junyan},
  title = {Automated Restarting Fast Proximal Gradient Descent Method for Single-View Cone-Beam X-ray Luminescence Computed Tomography Based on Depth Compensation},
  journal = {Bioengineering},
  year = {2024},
  volume = {11},
  number = {2},
  pages = {123},
  doi = {10.3390/bioengineering11020123}
}
Kostenlos starten →