High-Accuracy Neuro-Navigation with Computer Vision for Frameless Registration and Real-Time Tracking
Bioengineering · 07.12.2023 · 10 (12) · 1401
DOI: 10.3390/bioengineering10121401 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 07.12.2023. Verfasst von Isabella Chiurillo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Zeta Surgical Inc., Boston, MA 02111, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
For the past three decades, neurosurgeons have utilized cranial neuro-navigation systems, bringing millimetric accuracy to operating rooms worldwide. These systems require an operating room team, anesthesia, and, most critically, cranial fixation. As a result, treatments for acute neurosurgical conditions, performed urgently in emergency rooms or intensive care units on awake and non-immobilized patients, have not benefited from traditional neuro-navigation. These emergent procedures are performed freehand, guided only by anatomical landmarks with no navigation, resulting in inaccurate catheter placement and neurological deficits. A rapidly deployable image-guidance technology that offers highly accurate, real-time registration and is capable of tracking awake, moving patients is needed to improve patient safety. The Zeta Cranial Navigation System is currently the only non-fiducial-based, FDA-approved neuro-navigation device that performs real-time registration and continuous patient tracking. To assess this system’s performance, we performed registration and tracking of phantoms and human cadaver heads during controlled motions and various adverse surgical test conditions. As a result, we obtained millimetric or sub-millimetric target and surface registration accuracy. This rapid and accurate frameless neuro-navigation system for mobile subjects can enhance bedside procedure safety and expand the range of interventions performed with high levels of accuracy outside of an operating room.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Zeta Surgical Inc., Boston, MA 02111, USA.
- Department of Neurological Surgery, Massachusetts General Hospital, Boston, MA 02114, USA.
- Harvard Medical School, Boston, MA 02115, USA.
- Computational Neurosurgical Outcomes Center, Brigham and Women's Hospital, Boston, MA 02115, USA.
- Department of Neurological Surgery, Brigham and Women's Hospital, Boston, MA 02115, USA.
ORCID-Profile: Isabella Chiurillo, William B Gormley, Roman Stolyarov
Zitieren
APA
Chiurillo, I., Sha, R. M., Robertson, F. C., Liu, J., Li, J., Le Mau, H., Amich, J. M., Gormley, W. B., & Stolyarov, R. (2023). High-Accuracy Neuro-Navigation with Computer Vision for Frameless Registration and Real-Time Tracking. Bioengineering, 10(12), 1401. https://doi.org/10.3390/bioengineering10121401
Vancouver
Chiurillo I, Sha RM, Robertson FC, Liu J, Li J, Le Mau H, et al. High-Accuracy Neuro-Navigation with Computer Vision for Frameless Registration and Real-Time Tracking. Bioengineering. 2023;10(12):1401. doi:10.3390/bioengineering10121401
BibTeX
@article{Chiurillo2023,
author = {Chiurillo, Isabella and Sha, Raahil M and Robertson, Faith C and Liu, Jian and Li, Jacqueline and Le Mau, Hieu and Amich, Jose M and Gormley, William B and Stolyarov, Roman},
title = {High-Accuracy Neuro-Navigation with Computer Vision for Frameless Registration and Real-Time Tracking},
journal = {Bioengineering},
year = {2023},
volume = {10},
number = {12},
pages = {1401},
doi = {10.3390/bioengineering10121401}
}
EUVIMED