EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography

Tai-Ang Wang iD, Nguyễn Hoàng Trung, Hsiang-Chieh Lee iD, Cheng-Kuang Lee, Meng-Tsan Tsai iD, Yen-Li Wang

Bioengineering · 15.11.2023 · 10 (11) · 1317

DOI: 10.3390/bioengineering10111317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 15.11.2023. Verfasst von Tai-Ang Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, Taiwan, Chang Gung Memorial Hospital, National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dental caries on the crown’s surface is caused by the interaction of bacteria and carbohydrates, which then gradually alter the tooth’s structure. In addition, calculus is the root of periodontal disease. Optical coherence tomography (OCT) has been considered to be a promising tool for identifying dental caries; however, diagnosing dental caries in the early stage still remains challenging. In this study, we proposed an ultrahigh-resolution OCT (UHR-OCT) system with axial and transverse resolutions of 2.6 and 1.8 μm for differentiating the early-stage dental caries and calculus. The same teeth were also scanned by a conventional spectral-domain OCT (SD-OCT) system with an axial resolution of 7 μm. The results indicated that early-stage carious structures such as small cavities can be observed using UHR-OCT; however, the SD-OCT system with a lower resolution had difficulty identifying it. Moreover, the estimated surface roughness and the scattering coefficient of enamel were proposed for quantitatively differentiating the different stages of caries. Furthermore, the thickness of the calculus can be estimated from the UHR-OCT results. The results have demonstrated that UHR-OCT can detect caries and calculus in their early stages, showing that the proposed method for the quantitative evaluation of caries and calculus is potentially promising.

Schlagwörter

Stichwörter der Autor:innen

calculuscariesoptical coherence tomographyroughnessscattering

Autor:innen und Institutionen

  • Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan.
  • Department of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan.
  • Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan.
  • NVIDIA AI Technology Center, NVIDIA, Taipei 11492, Taiwan.
  • Department of Dermatology, Chang Gung Memorial Hospital, Linkou 33305, Taiwan.
  • Department of Periodontics, Chang Gung Memorial Hospital, Taoyuan 33378, Taiwan.

ORCID-Profile: Tai-Ang Wang, Hsiang-Chieh Lee, Meng-Tsan Tsai

Förderung

  • National Science and Technology Council, Taiwan
  • Chang Gung Memorial Hospital
  • National Science and Technology Council
  • National Taiwan University Royal Palm Elite Doctoral Scholarship

Zitieren

APA

Wang, T. A., Trung, N. H., Lee, H. C., Lee, C. K., Tsai, M. T., & Wang, Y. L. (2023). Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography. Bioengineering, 10(11), 1317. https://doi.org/10.3390/bioengineering10111317

Vancouver

Wang TA, Trung NH, Lee HC, Lee CK, Tsai MT, Wang YL. Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography. Bioengineering. 2023;10(11):1317. doi:10.3390/bioengineering10111317

BibTeX
@article{Wang2023,
  author = {Wang, Tai-Ang and Trung, Nguyễn Hoàng and Lee, Hsiang-Chieh and Lee, Cheng-Kuang and Tsai, Meng-Tsan and Wang, Yen-Li},
  title = {Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography},
  journal = {Bioengineering},
  year = {2023},
  volume = {10},
  number = {11},
  pages = {1317},
  doi = {10.3390/bioengineering10111317}
}