EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pre-Planning the Surgical Target for Optimal Implant Positioning in Robotic-Assisted Total Knee Arthroplasty

Periklis Tzanetis iD, René Fluit iD, Kevin de Souza iD, Seonaid Robertson, Bart Koopman, Nico Verdonschot

Bioengineering · 28.04.2023 · 10 (5) · 543

DOI: 10.3390/bioengineering10050543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 28.04.2023. Verfasst von Periklis Tzanetis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechanical Engineering, University of Twente, 7522 LW Enschede, The Netherlands. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stryker (Ireland), Stryker European Operations Ltd..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Robotic-assisted total knee arthroplasty can attain highly accurate implantation. However, the target for optimal positioning of the components remains debatable. One of the proposed targets is to recreate the functional status of the pre-diseased knee. The aim of this study was to demonstrate the feasibility of reproducing the pre-diseased kinematics and strains of the ligaments and, subsequently, use that information to optimize the position of the femoral and tibial components. For this purpose, we segmented the pre-operative computed tomography of one patient with knee osteoarthritis using an image-based statistical shape model and built a patient-specific musculoskeletal model of the pre-diseased knee. This model was initially implanted with a cruciate-retaining total knee system according to mechanical alignment principles; and an optimization algorithm was then configured seeking the optimal position of the components that minimized the root-mean-square deviation between the pre-diseased and post-operative kinematics and/or ligament strains. With concurrent optimization for kinematics and ligament strains, we managed to reduce the deviations from 2.4 ± 1.4 mm (translations) and 2.7 ± 0.7° (rotations) with mechanical alignment to 1.1 ± 0.5 mm and 1.1 ± 0.6°, and the strains from 6.5% to lower than 3.2% over all the ligaments. These findings confirm that adjusting the implant position from the initial plan allows for a closer match with the pre-diseased biomechanical situation, which can be utilized to optimize the pre-planning of robotic-assisted surgery.

Schlagwörter

Stichwörter der Autor:innen

musculoskeletal modelingoptimal implant positionpre-diseased kneepre-operative planningrobotic-assisted total knee arthroplasty

Autor:innen und Institutionen

  • Department of Biomechanical Engineering, University of Twente, 7522 LW Enschede, The Netherlands.
  • Faculty of Science and Engineering, University of Groningen, 9747 AG Groningen, The Netherlands.
  • Orthopaedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands.
  • Stryker, Manchester M20 2HJ, UK.

ORCID-Profile: Periklis Tzanetis, René Fluit, Kevin de Souza

Förderung

  • Stryker (Ireland)
  • Stryker European Operations Ltd.

Zitieren

APA

Tzanetis, P., Fluit, R., de Souza, K., Robertson, S., Koopman, B., & Verdonschot, N. (2023). Pre-Planning the Surgical Target for Optimal Implant Positioning in Robotic-Assisted Total Knee Arthroplasty. Bioengineering, 10(5), 543. https://doi.org/10.3390/bioengineering10050543

Vancouver

Tzanetis P, Fluit R, de Souza K, Robertson S, Koopman B, Verdonschot N. Pre-Planning the Surgical Target for Optimal Implant Positioning in Robotic-Assisted Total Knee Arthroplasty. Bioengineering. 2023;10(5):543. doi:10.3390/bioengineering10050543

BibTeX
@article{Tzanetis2023,
  author = {Tzanetis, Periklis and Fluit, René and de Souza, Kevin and Robertson, Seonaid and Koopman, Bart and Verdonschot, Nico},
  title = {Pre-Planning the Surgical Target for Optimal Implant Positioning in Robotic-Assisted Total Knee Arthroplasty},
  journal = {Bioengineering},
  year = {2023},
  volume = {10},
  number = {5},
  pages = {543},
  doi = {10.3390/bioengineering10050543}
}
Kostenlos starten →