Degradation-Aware Management of Second-Life Lithium-Ion Banks Using Probabilistic SOH Derating in Isolated Microgrids

Víctor Olivero-Ortiz, Carlos Robles-Algarín, Ingrid Oliveros Pantoja

Batteries · 12.11.2026 · 12 (11) · 485

DOI: 10.3390/batteries12110485 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Batteries, online erschienen am 12.11.2026. Verfasst von Víctor Olivero-Ortiz und 2 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Technology and Innovation of Colombia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Second-life lithium-ion banks in isolated microgrids combine heterogeneous, partially degraded cells with harsh tropical operation, yet conventional battery management reacts to voltage limits only once they are reached. This work proposes a degradation-aware battery management system in which the probabilistic state-of-health (SOH) estimate of each cell, obtained by Gaussian process regression, sets a proactive current-derating factor through an uncertainty-penalized effective SOH (μ−2σ), so that estimation uncertainty becomes a control variable. The estimator was validated on four public datasets spanning four chemistry/format combinations, including six LG INR21700-M50T cells with a measured 50-month electric-vehicle-to-storage transition (out-of-fold RMSE 0.28% SOH; 0.69–2.29% on NASA, CALCE, and RWTH benchmarks). An independent 36-cell pack dataset confirms the premise: 14 cells fall below 3.0 V while the pack voltage still reads nominal. At the cycle level, the derating removes every envelope violation of unprotected operation while extracting 3.5% more energy than a safe per-cell cutoff. Over 1500 simulated days of an off-grid photovoltaic microgrid in the Colombian non-interconnected zones, with a bank built from the six measured second-life cells, the strategy preserves 6.5 SOH percentage points at zero loss of supply, rising to 11.8 pp at 35 °C and 13.9 pp for a pre-aged bank, where only the managed bank avoids end of life. The control law is algebraic (∼2 μs per evaluation), computationally compatible with low-cost embedded implementation.

Förderung

  • Ministry of Science, Technology and Innovation of Colombia

Zitieren

APA

Olivero-Ortiz, V., Robles-Algarín, C., & Pantoja, I. O. (2026). Degradation-Aware Management of Second-Life Lithium-Ion Banks Using Probabilistic SOH Derating in Isolated Microgrids. Batteries, 12(11), 485. https://doi.org/10.3390/batteries12110485

Vancouver

Olivero-Ortiz V, Robles-Algarín C, Pantoja IO. Degradation-Aware Management of Second-Life Lithium-Ion Banks Using Probabilistic SOH Derating in Isolated Microgrids. Batteries. 2026;12(11):485. doi:10.3390/batteries12110485

BibTeX
@article{OliveroOrtiz2026,
  author = {Olivero-Ortiz, Víctor and Robles-Algarín, Carlos and Pantoja, Ingrid Oliveros},
  title = {Degradation-Aware Management of Second-Life Lithium-Ion Banks Using Probabilistic SOH Derating in Isolated Microgrids},
  journal = {Batteries},
  year = {2026},
  volume = {12},
  number = {11},
  pages = {485},
  doi = {10.3390/batteries12110485}
}