EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Electrochemical Aging on the Mechanical–Electrical–Thermal Safety Response of Tabless 4695 Cylindrical Cells Under Quasi-Static Indentation

Richard Polzer, Eva Heider, Christian Ellersdorfer, Ute Golla-Schindler, Carlos Antônio Rufino Júnior, Sergej Diel, Hans-Georg Schweiger

Batteries · 20.05.2026 · 12 (5) · 179

DOI: 10.3390/batteries12050179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Batteries, online erschienen am 20.05.2026. Verfasst von Richard Polzer und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Access Publication Fund of Technische Hochschule Ingolstadt.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical aging can alter the mechanical abuse tolerance of lithium-ion cells, but evidence for large-format tabless cylindrical cells remains limited. This study investigates commercial steel-cased 4695 cells under quasi-static hemispherical indentation at 100% State-of-Charge. Fresh cells were compared with two aged groups brought to 80% remaining capacity by either room-temperature cycling at 20 °C and 20 A or low-temperature/high-current cycling at −10 °C and 45 A. Aging shifted the onset of a major internal short circuit to lower displacement, force, and absorbed mechanical work. Relative to fresh cells, the mean displacement at internal short-circuit onset decreased by 15.9% after aging at 20 °C and 20 A and by 22.1% after aging at −10 °C and 45 A, while the corresponding force decreased by 10.8% and 19.4%. The absorbed mechanical work to short-circuit onset decreased by 24.0% and 37.3%, respectively. Peak surface temperatures did not clearly separate the groups, whereas integrating the surface-temperature rise over the first 30 s after short-circuit onset revealed an increase from 6894 Ks in fresh cells to 9872 Ks and 13,777 Ks in the two aged groups. The experiments also revealed a change in observed venting behavior, with top-terminal venting occurring more frequently in aged cells. These results indicate that, under the tested conditions, aging history can reduce mechanical abuse tolerance and modify post-failure severity in large-format cylindrical cells.

Förderung

  • Open Access Publication Fund of Technische Hochschule Ingolstadt

Zitieren

APA

Polzer, R., Heider, E., Ellersdorfer, C., Golla-Schindler, U., Júnior, C. A. R., Diel, S., & Schweiger, H. (2026). Effect of Electrochemical Aging on the Mechanical–Electrical–Thermal Safety Response of Tabless 4695 Cylindrical Cells Under Quasi-Static Indentation. Batteries, 12(5), 179. https://doi.org/10.3390/batteries12050179

Vancouver

Polzer R, Heider E, Ellersdorfer C, Golla-Schindler U, Júnior CAR, Diel S, et al. Effect of Electrochemical Aging on the Mechanical–Electrical–Thermal Safety Response of Tabless 4695 Cylindrical Cells Under Quasi-Static Indentation. Batteries. 2026;12(5):179. doi:10.3390/batteries12050179

BibTeX
@article{Polzer2026,
  author = {Polzer, Richard and Heider, Eva and Ellersdorfer, Christian and Golla-Schindler, Ute and Júnior, Carlos Antônio Rufino and Diel, Sergej and Schweiger, Hans-Georg},
  title = {Effect of Electrochemical Aging on the Mechanical–Electrical–Thermal Safety Response of Tabless 4695 Cylindrical Cells Under Quasi-Static Indentation},
  journal = {Batteries},
  year = {2026},
  volume = {12},
  number = {5},
  pages = {179},
  doi = {10.3390/batteries12050179}
}
Kostenlos starten →