Active Battery-Health Diagnostics for Real-World Applications Using a Bi-Directional Charger
Batteries · 21.04.2026 · 12 (4) · 146
DOI: 10.3390/batteries12040146 ↗Kurz gefasst
Fachartikel in der Zeitschrift Batteries, online erschienen am 21.04.2026. Verfasst von Tim Meulenbroeks und 6 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union’s Horizon 2020 research and innovation program.
Abstract (Originalsprache)
Battery health data from real-world applications are vital for optimizing and predicting battery lifetime. This study presents the design and verification of an active battery-diagnostic system and method to collect such data. The system measures battery pack capacity and resistance by applying a diagnostic protocol via a bi-directional charger. This was demonstrated on a stationary-energy-storage application, under real-world conditions, to verify the system’s design requirements. Measurements at the start and the end of the demonstration period of a month resulted in an observed degradation of 1.79 ± 0.34% battery capacity and an increase of 1.42 ± 0.75% in battery resistance. The successful measurements of capacity and resistance prove the compatibility of the system with real-world battery systems and confirm the design requirements were met. The system was able to perform autonomous and in situ measurements while only requiring the addition of software to the battery management system and by using the bi-directional charger of the energy storage system. By repeatedly applying the same diagnostic protocol over time, this system enables consistent tracking of battery health.
Förderung
- European Union’s Horizon 2020 research and innovation program
Zitieren
APA
Meulenbroeks, T., Köhler, T., Hasan, M. M., Reymond-Laruina, F., Geury, T., Hegazy, O., & Wilkins, S. (2026). Active Battery-Health Diagnostics for Real-World Applications Using a Bi-Directional Charger. Batteries, 12(4), 146. https://doi.org/10.3390/batteries12040146
Vancouver
Meulenbroeks T, Köhler T, Hasan MM, Reymond-Laruina F, Geury T, Hegazy O, et al. Active Battery-Health Diagnostics for Real-World Applications Using a Bi-Directional Charger. Batteries. 2026;12(4):146. doi:10.3390/batteries12040146
BibTeX
@article{Meulenbroeks2026,
author = {Meulenbroeks, Tim and Köhler, Thomas and Hasan, Md. Mahamudul and Reymond-Laruina, Frédéric and Geury, Thomas and Hegazy, Omar and Wilkins, Steven},
title = {Active Battery-Health Diagnostics for Real-World Applications Using a Bi-Directional Charger},
journal = {Batteries},
year = {2026},
volume = {12},
number = {4},
pages = {146},
doi = {10.3390/batteries12040146}
}