Calibration for a Redundant Serial Robot Based on an Elasto-Geometrical Model and an Adaptive Identification Algorithm
Automation · 13.11.2026 · 7 (6) · 188
DOI: 10.3390/automation7060188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Automation, online erschienen am 13.11.2026. Verfasst von Bin Wang und 2 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
This paper proposes a novel elasto-geometrical coupling calibration and an adaptive parameter identification method for flexible redundant manipulators. For the modeling, an elasto-geometrical coupling calibration model containing kinematic parameter errors and non-kinematic errors is constructed. Secondly, an adaptive identification rule is formulated to suppress the elasto-geometrical modeling errors according to the residual linearization errors in each iteration, thus obtaining accurate identification results even in the case of highly elastic joints. Thirdly, a dual-target measuring strategy based on multi-source sensing is designed to obtain high-precision hand-eye data; thus, lightweight sensors and a vision system suitable for flexible light-load manipulators can be practically used for the calibration. As revealed by simulation tests, the newly developed identification algorithm can progressively compensate for considerable linearization modeling discrepancies for a redundant robotic arm with 12 highly elastic joints. All error parameters are estimated with an accuracy above 99% through iterative updates. Corresponding experiments are carried out on an eight-joint cable-driven elastic redundant manipulator, and the results indicate the new calibration method reaches the fastest algorithm convergence and residuals at the same level when compared with two traditional ones.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, B., Jiang, Z., & Xie, S. (2026). Calibration for a Redundant Serial Robot Based on an Elasto-Geometrical Model and an Adaptive Identification Algorithm. Automation, 7(6), 188. https://doi.org/10.3390/automation7060188
Vancouver
Wang B, Jiang Z, Xie S. Calibration for a Redundant Serial Robot Based on an Elasto-Geometrical Model and an Adaptive Identification Algorithm. Automation. 2026;7(6):188. doi:10.3390/automation7060188
BibTeX
@article{Wang2026,
author = {Wang, Bin and Jiang, Zhouxiang and Xie, Shuhui},
title = {Calibration for a Redundant Serial Robot Based on an Elasto-Geometrical Model and an Adaptive Identification Algorithm},
journal = {Automation},
year = {2026},
volume = {7},
number = {6},
pages = {188},
doi = {10.3390/automation7060188}
}