EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Target Tracking-Based Online Calibration of UAV Electro-Optical Pod Installation Errors

Yong Xu, Jin Liu, Hongtao Yan, An Wang, Haihang Xu, Yue Ma, Tian Yao

Automation · 01.04.2026 · 7 (2) · 59

DOI: 10.3390/automation7020059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Automation, online erschienen am 01.04.2026. Verfasst von Yong Xu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the “visual perception hub” of unmanned aerial vehicles (UAVs), electro-optical (EO) pods play an increasingly critical role in tasks such as intelligence gathering, situational awareness, target tracking, and localization. With the expanding scope and depth of UAV applications, higher demands are placed on the precision and adaptability of installation error calibration techniques for EO pods. Current mainstream calibration methods typically require specialized procedures under constrained conditions, while few approaches integrate existing UAV system capabilities and mission requirements, which leads to cumbersome, time-consuming processes and suboptimal alignment between calibration outcomes and task objectives. This paper proposes an online calibration method for UAV EO pod installation errors based on target tracking, which can rapidly compute the optimal closed-form solution for installation errors by leveraging UAV tracking missions. First, an observation equation for pod installation errors is established using tracking results. Second, multi-temporal observations are combined to model the calibration problem as an optimal rotation matrix estimation task, and then the optimal closed-form solution for installation errors is derived. Concurrently, a statistics-based approximate calibration method is introduced specifically for tracking missions. Furthermore, an online calibration system compatible with diverse UAV platforms is designed, along with different rapid calibration schemes for emergency response scenarios, fully incorporating existing system capabilities and mission needs. Finally, a fixed-wing UAV experimental platform is developed, with calibration tests conducted under various flight regimes. Experimental results validate the feasibility and robustness of the proposed methodology.

Zitieren

APA

Xu, Y., Liu, J., Yan, H., Wang, A., Xu, H., Ma, Y., & Yao, T. (2026). Target Tracking-Based Online Calibration of UAV Electro-Optical Pod Installation Errors. Automation, 7(2), 59. https://doi.org/10.3390/automation7020059

Vancouver

Xu Y, Liu J, Yan H, Wang A, Xu H, Ma Y, et al. Target Tracking-Based Online Calibration of UAV Electro-Optical Pod Installation Errors. Automation. 2026;7(2):59. doi:10.3390/automation7020059

BibTeX
@article{Xu2026,
  author = {Xu, Yong and Liu, Jin and Yan, Hongtao and Wang, An and Xu, Haihang and Ma, Yue and Yao, Tian},
  title = {Target Tracking-Based Online Calibration of UAV Electro-Optical Pod Installation Errors},
  journal = {Automation},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {59},
  doi = {10.3390/automation7020059}
}
Kostenlos starten →