Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults
Audiology Research · 21.11.2026 · 16 (6) · 175
DOI: 10.3390/audiolres16060175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Audiology Research, online erschienen am 21.11.2026. Verfasst von Santhoshi Ramamoorthy und 1 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Video-oculography (VOG) recordings may contain physiological and non-physiological artifacts that can mimic genuine oculomotor abnormality, particularly along the vertical axis. This exploratory pilot study introduced the VOG Artifact Assessment Questionnaire (VAQ) and examined the association between artifact load and axis-specific saccadic and smooth pursuit measures.
Methods
Thirty healthy adults aged 18–25 years underwent horizontal and vertical saccade and smooth pursuit testing on a VOG system. Artifacts were scored using the 17-item VAQ in real time during recording and offline from the stored recordings (all 17 items at T1; the 11 items that can be scored offline at T2), and the Total Artifact Score (TAS; range of 0–25) was calculated from the final item scores. Associations between the continuous TAS (rank order) and latency, peak velocity, precision, and gain were analyzed using Kendall’s τ-b and a linear mixed model, with Holm correction; participants were also divided into tertile groups by TAS rank order.
Results
The VAQ showed high internal consistency (Cronbach’s α = 0.913). No saccade or smooth pursuit measure was associated with the continuous TAS (Kendall’s τ-b −0.15 to +0.14; all unadjusted p ≥ 0.26; all Holm-adjusted p = 1.0), and this held at every flag threshold tested (k = 1 to 7 and a mixed rule; no unadjusted p < 0.05 in 64 tests). Comparison across TAS-tertile groups (n = 11, 11 and 8) yielded the same result (τ-b −0.16 to +0.13; all unadjusted p ≥ 0.28). An exploratory pooled mixed model also showed no association (−0.015 SD per TAS point, 95% CI −0.053 to +0.022).
Conclusions
In this small sample of healthy adults, no association between VAQ-derived artifact load and saccadic or smooth pursuit measures was detected, although wide confidence intervals mean that moderate effects cannot be excluded. The VAQ and its provisional categories remain unvalidated and require testing in larger, independent and clinical samples with blinded raters.
Zitieren
APA
Ramamoorthy, S., & Samayan, K. (2026). Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults. Audiology Research, 16(6), 175. https://doi.org/10.3390/audiolres16060175
Vancouver
Ramamoorthy S, Samayan K. Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults. Audiology Research. 2026;16(6):175. doi:10.3390/audiolres16060175
BibTeX
@article{Ramamoorthy2026,
author = {Ramamoorthy, Santhoshi and Samayan, Kala},
title = {Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults},
journal = {Audiology Research},
year = {2026},
volume = {16},
number = {6},
pages = {175},
doi = {10.3390/audiolres16060175}
}