EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pressure-Less Acoustic Immittance-Derived Middle Ear Resonance Frequency: Repeatability and Comparison with Multifrequency Tympanometry

Zsuzsanna Piros iD, Szilárd Gyula Rezes, Rita Kiss iD, Beáta Lelesz, Gyula Ujlaki iD, Béla Juhász, Zoltán Szilvássy

Audiology Research · 30.06.2026 · 16 (4) · 98

DOI: 10.3390/audiolres16040098 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Audiology Research, online erschienen am 30.06.2026. Verfasst von Zsuzsanna Piros und 6 weiteren Autor:innen. Beteiligte Einrichtung: Szilvássy Judit Audiology Centre, Department of Otorhinolaryngology and Head and Neck Surgery, University of Debrecen Clinical Centre, Nagyerdei St. …. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Debrecen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: This study evaluated the intra-session repeatability, reliability, and clinical consistency of resonance frequency derived from pressure-less acoustic immittance (PLAI), and compared the results with those obtained using conventional multifrequency tympanometry under identical clinical conditions.

Methods

In this pilot methodological comparison study, resonance frequency (RF) measurements were obtained in 15 subjects (30 ears) using multifrequency tympanometry (MFT) and pressure-less acoustic immittance (PLAI). Three consecutive measurements were performed for each ear using both methods. Agreement between methods was evaluated using Bland–Altman analysis. Within-method repeatability was assessed using range, coefficient of variation, repeatability coefficient, and intraclass correlation coefficients.

Results

PLAI demonstrated lower intra-session variability than MFT. The mean within-series SD was 96.6 Hz for MFT and 10.5 Hz for PLAI. The coefficient of variation was 9.3% for MFT and 3.2% for PLAI, while intraclass correlation coefficients were 0.60 and 0.83, respectively. The repeatability coefficient was ±367 Hz for MFT and ±47 Hz for PLAI. Bland–Altman analysis revealed a systematic difference between the two methods, with a mean bias of 580.7 Hz and 95% limits of agreement between 247.5 Hz and 913.9 Hz, indicating that the two methods are not interchangeable.

Conclusions

PLAI demonstrated higher repeatability than MFT. Its lower variability may support a more consistent clinical interpretation; PLAI-derived RF may therefore represent a stable method-specific parameter for middle ear assessment. However, RF values should be interpreted within method-specific frameworks.

Schlagwörter

Stichwörter der Autor:innen

Bland–Altman analysisintraclass correlation coefficientmethodological comparison studymiddle ear diagnosticsmiddle ear mechanicsmiddle ear resonance frequencymultifrequency tympanometrypressure-less acoustic immittancereliabilityrepeatability

Autor:innen und Institutionen

  • Szilvássy Judit Audiology Centre, Department of Otorhinolaryngology and Head and Neck Surgery, University of Debrecen Clinical Centre, Nagyerdei St. 98, H-4032 Debrecen, Hungary.
  • Doctoral School of Nutrition and Food Sciences, University of Debrecen, H-4032 Debrecen, Hungary.
  • Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Debrecen, Nagyerdei St. 98, H-4032 Debrecen, Hungary.

ORCID-Profile: Zsuzsanna Piros, Rita Kiss, Gyula Ujlaki

Förderung

  • University of Debrecen

Zitieren

APA

Piros, Z., Rezes, S. G., Kiss, R., Lelesz, B., Ujlaki, G., Juhász, B., & Szilvássy, Z. (2026). Pressure-Less Acoustic Immittance-Derived Middle Ear Resonance Frequency: Repeatability and Comparison with Multifrequency Tympanometry. Audiology Research, 16(4), 98. https://doi.org/10.3390/audiolres16040098

Vancouver

Piros Z, Rezes SG, Kiss R, Lelesz B, Ujlaki G, Juhász B, et al. Pressure-Less Acoustic Immittance-Derived Middle Ear Resonance Frequency: Repeatability and Comparison with Multifrequency Tympanometry. Audiology Research. 2026;16(4):98. doi:10.3390/audiolres16040098

BibTeX
@article{Piros2026,
  author = {Piros, Zsuzsanna and Rezes, Szilárd Gyula and Kiss, Rita and Lelesz, Beáta and Ujlaki, Gyula and Juhász, Béla and Szilvássy, Zoltán},
  title = {Pressure-Less Acoustic Immittance-Derived Middle Ear Resonance Frequency: Repeatability and Comparison with Multifrequency Tympanometry},
  journal = {Audiology Research},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {98},
  doi = {10.3390/audiolres16040098}
}
Kostenlos starten →