EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Indoor Exposure to Wildfire Smoke: A Critical Review of Infiltration, Assessment, and Removal

Runcheng Fang, Khawla Ismail-Abderrezaq, Jun Wang

Atmosphere · 21.11.2026 · 17 (12) · 1156

DOI: 10.3390/atmos17121156 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Atmosphere, online erschienen am 21.11.2026. Verfasst von Runcheng Fang und 2 weiteren Autor:innen. Die Arbeit nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Occupational Safety and Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Buildings can reduce exposure to wildfire smoke, although protection varies with pollutant properties, air exchange, filtration, and occupant activity. This critical review examines field measurements, intervention studies, and building models, focusing on the interpretation of indoor fine particulate matter (PM2.5). Indoor concentrations below outdoor levels may still represent substantial exposure, and a decline in the indoor–outdoor ratio alone does not demonstrate intervention effectiveness. Sensor networks document considerable variation among buildings, while smaller field studies characterize the operating conditions associated with that variation. Portable filtration generally reduces particle concentrations; however, short room experiments, sequential household studies, and concurrent controlled comparisons estimate different effects. Higher outdoor concentrations increase residual indoor pollution but do not necessarily reduce fractional filtration effectiveness when transport and removal rates are unchanged. Evidence on gaseous and semi-volatile pollutants remains limited, and particle measurements alone cannot characterize recovery after wildfire smoke exposure. Protection also depends on ventilation and thermal requirements, device noise, maintenance, and access to cleaner spaces. Interpretation of the evidence requires explicit definitions of the pollutant metric, comparator, building operation, and exposure period. Event-triggered controlled studies, synchronized indoor–outdoor measurements, verified cleaner operation, and personal exposure assessment are needed to determine the transferability of building interventions.

Förderung

  • National Institute for Occupational Safety and Health

Zitieren

APA

Fang, R., Ismail-Abderrezaq, K., & Wang, J. (2026). Indoor Exposure to Wildfire Smoke: A Critical Review of Infiltration, Assessment, and Removal. Atmosphere, 17(12), 1156. https://doi.org/10.3390/atmos17121156

Vancouver

Fang R, Ismail-Abderrezaq K, Wang J. Indoor Exposure to Wildfire Smoke: A Critical Review of Infiltration, Assessment, and Removal. Atmosphere. 2026;17(12):1156. doi:10.3390/atmos17121156

BibTeX
@article{Fang2026,
  author = {Fang, Runcheng and Ismail-Abderrezaq, Khawla and Wang, Jun},
  title = {Indoor Exposure to Wildfire Smoke: A Critical Review of Infiltration, Assessment, and Removal},
  journal = {Atmosphere},
  year = {2026},
  volume = {17},
  number = {12},
  pages = {1156},
  doi = {10.3390/atmos17121156}
}
Kostenlos starten →