Measurement Duration for Reliable Indoor Radon Testing
Atmosphere · 22.07.2026 · 17 (7) · 706
DOI: 10.3390/atmos17070706 ↗Kurz gefasst
Fachartikel in der Zeitschrift Atmosphere, online erschienen am 22.07.2026. Verfasst von Andrey Tsapalov und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS Program for Forming Japan’s Peak Research Universities, JSPS KAKENHI.
Abstract (Originalsprache)
Although radon measurements have been carried out in most countries for several decades, a rigorous methodology for assessing the reliability (as well as the effectiveness) of indoor radon testing between short-term and long-term measurements has not yet been established at either the national or international level. National regulators, lacking scientific justification, arbitrarily set the duration of indoor radon testing (from a few minutes to several months) preferring long-term measurements simply because it “seems more reliable”. To solve this fundamental regulation problem, an original (innovative) methodology is proposed based on the algorithms of the previously published Rational Method for indoor radon testing, which ensures 95% decision-making reliability within modern metrological concepts. A comparison of the reliability (and effectiveness) between short-term and long-term measurements can be made by taking into account the radon situation at both national and global levels. The obtained dependence of the mean (among 26 countries) percentage of definite (reliable) decisions vs. the duration of measurements indicates: (i) the greater effectiveness of using short-term measurements compared to long-term ones, as well as (ii) the excessive focus of national and international regulators only on instrumental uncertainty within QA/QC to the detriment of temporal (key) uncertainty in decision-making. Key conclusion: The established practice of radon regulation on both global and national levels contains a number of underlying myths, and therefore clearly needs to be rethought and updated within a rational (scientific) strategy. A vital necessity are specific experimental (field) studies to verify (clarify) the national values of the temporal (key) uncertainty of indoor radon (and thoron EEC), as well as the creation of simple and effective (inexpensive but reliable) IoT tools for large-scale measurements of indoor radon through the involvement (and at the expense) of the population.
Förderung
- JSPS Program for Forming Japan’s Peak Research Universities
- JSPS KAKENHI
Zitieren
APA
Tsapalov, A., & Kranrod, C. (2026). Measurement Duration for Reliable Indoor Radon Testing. Atmosphere, 17(7), 706. https://doi.org/10.3390/atmos17070706
Vancouver
Tsapalov A, Kranrod C. Measurement Duration for Reliable Indoor Radon Testing. Atmosphere. 2026;17(7):706. doi:10.3390/atmos17070706
BibTeX
@article{Tsapalov2026,
author = {Tsapalov, Andrey and Kranrod, Chutima},
title = {Measurement Duration for Reliable Indoor Radon Testing},
journal = {Atmosphere},
year = {2026},
volume = {17},
number = {7},
pages = {706},
doi = {10.3390/atmos17070706}
}
EUVIMED