EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

One Operating Room, Two Thermal Worlds: Determinants and Limits of Thermal Comfort for Surgical Staff

Mareike Ziegler, Hans-Martin Seipp, Thomas Steffens, Michael Klages, Jennifer Herzog-Niescery

Atmosphere · 15.05.2026 · 17 (5) · 503

DOI: 10.3390/atmos17050503 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Atmosphere, online erschienen am 15.05.2026. Verfasst von Mareike Ziegler und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal comfort in operating rooms is critical for staff performance and safety, but conflicting requirements among professional groups create complex challenges. In a real operating room with a unidirectional airflow system, air velocity and temperature were measured, and predicted thermal sensation as well as the proportion of dissatisfied staff were calculated according to international standards. Analyses included surgeons, technical assistants, and anesthesiologists, considering clothing insulation, task-specific activity, gender, body mass index, and the use of lead aprons of different weights. Gender, body mass index, and temperature strongly influenced thermal comfort, whereas variation in air velocity had only minor effects. Thermal comfort targets diverged markedly between professional groups. Under identical conditions in our operating room, up to 75% of male surgeons wearing lead aprons experienced pronounced heat stress, whereas approximately 22% of female anesthesiologists experienced predominantly cold discomfort. Female surgeons would require temperatures as low as 16 °C to achieve thermal comfort, while nearly 50% of male surgeons perceived even this temperature as uncomfortably warm. Removing lead aprons reduced heat stress in surgeons but increased cold stress in anesthesiologists. Higher body-mass index improved heat dissipation in surgeons but aggravated cold stress in anesthesiologists. These findings demonstrate that uniform temperature settings cannot ensure thermal comfort for all professional groups. Practical implications include the need for role-specific strategies, such as targeted personal cooling or warming measures and differentiated clothing systems, to improve working conditions and maintain patient safety in operating rooms.

Zitieren

APA

Ziegler, M., Seipp, H., Steffens, T., Klages, M., & Herzog-Niescery, J. (2026). One Operating Room, Two Thermal Worlds: Determinants and Limits of Thermal Comfort for Surgical Staff. Atmosphere, 17(5), 503. https://doi.org/10.3390/atmos17050503

Vancouver

Ziegler M, Seipp H, Steffens T, Klages M, Herzog-Niescery J. One Operating Room, Two Thermal Worlds: Determinants and Limits of Thermal Comfort for Surgical Staff. Atmosphere. 2026;17(5):503. doi:10.3390/atmos17050503

BibTeX
@article{Ziegler2026,
  author = {Ziegler, Mareike and Seipp, Hans-Martin and Steffens, Thomas and Klages, Michael and Herzog-Niescery, Jennifer},
  title = {One Operating Room, Two Thermal Worlds: Determinants and Limits of Thermal Comfort for Surgical Staff},
  journal = {Atmosphere},
  year = {2026},
  volume = {17},
  number = {5},
  pages = {503},
  doi = {10.3390/atmos17050503}
}
Kostenlos starten →