In Situ Measurement of Radon Exhalation Rate of Building Materials with Leakage Compensation
Atmosphere · 12.03.2026 · 17 (3) · 289
DOI: 10.3390/atmos17030289 ↗Kurz gefasst
Fachartikel in der Zeitschrift Atmosphere, online erschienen am 12.03.2026. Verfasst von Hongjie Nan und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China.
Abstract (Originalsprache)
Building materials have become a predominant source of indoor radon in mid- to high-rise buildings, making in situ measurement of radon exhalation rates from building surfaces essential for identifying radon sources and assessing associated risks. Based on practical survey requirements—addressing sealing leakage at chamber edges and ensuring device portability—this study developed an improved in situ measurement method integrated with leakage compensation through theoretical analysis and experimental validation. The method employs an acrylic accumulation chamber and a portable passive radon detector, adopts a 24 h continuous measurement duration, and processes radon concentration data using an exponential fitting approach. Comparative experiments with the activated carbon method demonstrated good consistency between the two methods. Furthermore, small-scale in situ measurements were conducted in the Beijing area, covering diverse building materials (concrete, brick), surface treatments (cement plaster, coating, wallpaper), and structural components (walls, floors). The results, which varied widely from 0.13 ± 0.11 to 28.00 ± 4.87 Bq/m2·h, confirm the reliability and applicability of the method for in situ determination of radon exhalation rates from interior building surfaces.
Förderung
- the National Natural Science Foundation of China
Zitieren
APA
Nan, H., Zhang, L., Guo, Q., & Ding, B. (2026). In Situ Measurement of Radon Exhalation Rate of Building Materials with Leakage Compensation. Atmosphere, 17(3), 289. https://doi.org/10.3390/atmos17030289
Vancouver
Nan H, Zhang L, Guo Q, Ding B. In Situ Measurement of Radon Exhalation Rate of Building Materials with Leakage Compensation. Atmosphere. 2026;17(3):289. doi:10.3390/atmos17030289
BibTeX
@article{Nan2026,
author = {Nan, Hongjie and Zhang, Lei and Guo, Qiuju and Ding, Bowei},
title = {In Situ Measurement of Radon Exhalation Rate of Building Materials with Leakage Compensation},
journal = {Atmosphere},
year = {2026},
volume = {17},
number = {3},
pages = {289},
doi = {10.3390/atmos17030289}
}
EUVIMED