Performance of Low-Cost Air Temperature Sensors and Applied Calibration Techniques—A Systematic Review
Atmosphere · 10.07.2025 · 16 (7) · 842
DOI: 10.3390/atmos16070842 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Atmosphere, online erschienen am 10.07.2025. Verfasst von Jabir Ali Abdinoor und 8 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University Research Fellowship Program of the Ministry for Culture and Innovation from The Source of the National Research, Development and Innovation Fund, TechCoach, AEDIH.
Abstract (Originalsprache)
Low-cost air temperature sensors are an emerging theme in environmental monitoring. These sensors offer the advantage of making microclimate monitoring feasible due to their affordability. However, they are limited by the quality of the data they provide; in many cases, they have been reported to have presented errors in the sensor readings. These errors have been shown to improve after calibration was applied. The lack of a comprehensive understanding of the available calibration techniques, models, and sensor types has led to studies presenting heterogeneity in models and techniques alongside different performance metrics. To address this gap, this study conducted a systematic review following the PRISMA guidelines, reviewing studies from 2015 to 2024 across the databases Web of Science and Scopus, alongside the search engine Google Scholar. The aim was to identify the calibration techniques and models, the commercially available low-cost air temperature sensors used, the performance metrics utilised, and the calibration settings. The findings presented three main categories of calibration models utilised in the collected studies: linear, polynomial, and machine learning. Twenty-two commercially available low-cost sensors were identified, with the DHT22 sensor being the most utilised. Indoor settings were identified as the most preferred for conducting calibrations. Key challenges included limitations in reported results for calibration by the studies, the use of different performance metrics across studies, insufficient studies conducting calibration, and the diversity in sensor types utilised.
Förderung
- University Research Fellowship Program of the Ministry for Culture and Innovation from The Source of the National Research, Development and Innovation Fund
- TechCoach
- AEDIH
Zitieren
APA
Abdinoor, J. A., Hashim, Z. K., Horváth, B., Zsebő, S., Stencinger, D., Hegedüs, G., Bede, L., Ijaz, A., & Kulmány, I. M. (2025). Performance of Low-Cost Air Temperature Sensors and Applied Calibration Techniques—A Systematic Review. Atmosphere, 16(7), 842. https://doi.org/10.3390/atmos16070842
Vancouver
Abdinoor JA, Hashim ZK, Horváth B, Zsebő S, Stencinger D, Hegedüs G, et al. Performance of Low-Cost Air Temperature Sensors and Applied Calibration Techniques—A Systematic Review. Atmosphere. 2025;16(7):842. doi:10.3390/atmos16070842
BibTeX
@article{Abdinoor2025,
author = {Abdinoor, Jabir Ali and Hashim, Zainulabdeen Khalaf and Horváth, Bálint and Zsebő, Sándor and Stencinger, Dávid and Hegedüs, Gergő and Bede, László and Ijaz, Ali and Kulmány, István Mihály},
title = {Performance of Low-Cost Air Temperature Sensors and Applied Calibration Techniques—A Systematic Review},
journal = {Atmosphere},
year = {2025},
volume = {16},
number = {7},
pages = {842},
doi = {10.3390/atmos16070842}
}
EUVIMED