EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Multiple HVAC Systems on Indoor Air VOC and Radon Concentrations from Vapor Intrusion During Seasonal Usage

John H Zimmerman iD, Alan Williams iD, Brian Schumacher iD, Christopher Lutes iD, Rohit Warrier, Brian Cosky, Ben Thompson, Chase W Holton, Kate Bronstein

Atmosphere · 27.03.2025 · 16 (4) · 378

DOI: 10.3390/atmos16040378 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Atmosphere, online erschienen am 27.03.2025. Verfasst von John H Zimmerman und 8 weiteren Autor:innen. Beteiligte Einrichtung: Office of Research and Development, U.S. Environmental Protection Agency, 109 TW Alexander Dr., P.O. Box 12055, Research Triangle Park, Durham, NC 27…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPA, Intramural EPA, United States Environmental Protection Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Subsurface contamination can migrate upward into overlying buildings, exposing the buildings’ inhabitants to contaminants that can cause detrimental health effects. This phenomenon is known as vapor intrusion (VI). When evaluating a building for VI, one must understand that seasonal and short-term variability are significant factors in determining the reasonable maximum exposure (RME) to the occupants. RME is a semi-quantitative term that refers to the lower portion of the high end of the exposure distribution—conceptually, above the 90th percentile exposure but less than the 98th percentile exposure. Samples were collected between December 2020 and April 2022 at six non-residential commercial buildings in Fairbanks, Alaska. The types of samples collected included indoor air (IA); outdoor air; subslab soil gas; soil gas; indoor radon; differential pressure; indoor and outdoor temperature; heating, ventilation, and air conditioning (HVAC) parameters; and other environmental factors. The buildings in close proximity to the volatile organic compound (VOC) source/release points presented less variability in indoor air concentrations of trichloroethylene (TCE) and tetrachloroethylene (PCE) compared to the buildings farther down gradient in the contaminated groundwater plume. The VOC data pattern for the source area buildings shows an outdoor air temperature-dominated behavior for indoor air concentrations in the summer season. HVAC system operations had less influence on long-term indoor air concentration trends than environmental factors, which is supported by similar indoor air concentration patterns independent of location within the plume. The use of soil temperature and indoor/outdoor temperatures as indicators and tracers (I&Ts) across the plume as predictors of the sampling period could produce a good estimation of the RME for the building occupants. These results, which show the use of soil temperature and indoor/outdoor temperatures as I&Ts, will help advance investigative methods for evaluation of VI in similar settings and thereby improve the protection of human health in indoor environments.

Schlagwörter

Stichwörter der Autor:innen

indicators and tracerspassive samplingreasonable maximum exposuresubslab soil gasvapor intrusionvolatile organic compounds

Autor:innen und Institutionen

  • Office of Research and Development, U.S. Environmental Protection Agency, 109 TW Alexander Dr., P.O. Box 12055, Research Triangle Park, Durham, NC 27711, USA.
  • Office of Research and Development, U.S. Environmental Protection Agency, 960 College Station Road, Athens, GA 30605, USA.
  • Jacobs, 1999 Bryan Street, Suite 1200, Dallas, TX 75201, USA.
  • GSI Environmental Inc., 13949 W. Colfax, No. 210, Lakewood, CO 80401, USA.
  • RTI International, 3040 E. Cornwallis Rd., Research Triangle Park, Durham, NC 27709, USA.

ORCID-Profile: John H Zimmerman, Alan Williams, Brian Schumacher, Christopher Lutes

Förderung

  • EPA
  • Intramural EPA
  • United States Environmental Protection Agency

Zitieren

APA

Zimmerman, J. H., Williams, A., Schumacher, B., Lutes, C., Warrier, R., Cosky, B., Thompson, B., Holton, C. W., & Bronstein, K. (2025). Impact of Multiple HVAC Systems on Indoor Air VOC and Radon Concentrations from Vapor Intrusion During Seasonal Usage. Atmosphere, 16(4), 378. https://doi.org/10.3390/atmos16040378

Vancouver

Zimmerman JH, Williams A, Schumacher B, Lutes C, Warrier R, Cosky B, et al. Impact of Multiple HVAC Systems on Indoor Air VOC and Radon Concentrations from Vapor Intrusion During Seasonal Usage. Atmosphere. 2025;16(4):378. doi:10.3390/atmos16040378

BibTeX
@article{Zimmerman2025,
  author = {Zimmerman, John H and Williams, Alan and Schumacher, Brian and Lutes, Christopher and Warrier, Rohit and Cosky, Brian and Thompson, Ben and Holton, Chase W and Bronstein, Kate},
  title = {Impact of Multiple HVAC Systems on Indoor Air VOC and Radon Concentrations from Vapor Intrusion During Seasonal Usage},
  journal = {Atmosphere},
  year = {2025},
  volume = {16},
  number = {4},
  pages = {378},
  doi = {10.3390/atmos16040378}
}
Kostenlos starten →