EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Scale Model Room Approach to Test the Performance of Airtight Membranes to Control Indoor Radon Levels and Radiation Exposure

Manuela Portaro, Ilaria Rocchetti, Paola Tuccimei, Gianfranco Galli, Michele Soligo, Cristina Longoni, Dino Vasquez

Atmosphere · 21.10.2024 · 15 (10) · 1260

DOI: 10.3390/atmos15101260 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Atmosphere, online erschienen am 21.10.2024. Verfasst von Manuela Portaro und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi “Roma Tre”, Dipartimento di Scienze, Università “Roma Tre”.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Indoor radon is one of the most significant contributors to lung cancer after smoking. Mitigation strategies based on protecting buildings with radon barrier materials, combined with home ventilation or room pressurization, are regularly used. A scale model room made from a porous ignimbrite rich in radon precursors was used as an analogue to test the efficiency of fifteen airtight membranes to reduce radon levels, also in combination with room pressurization. The results of these experiments were considered together with previous ones to propose the scale model room approach as a tool for rapidly evaluating the performance of specially designed radon barrier materials, and for radiation exposure assessment. Relative reduction of indoor radon (RIR) ranges from −20 to −94%. The most effective materials were FPO membrane, single-component silane-terminated polymer membranes and synthetic resins. The presence of additives likely modified the composition and structure of some products, improving their radon barrier capacity. The introduction of room pressurization further reduced radon levels in the model room where the membranes were applied. The overpressure necessary to reach RIRs of the order of 85–90% is very low for materials that powerfully stop radon even without ventilation, but necessarily higher for poorer membranes.

Förderung

  • Università degli Studi “Roma Tre”
  • Dipartimento di Scienze, Università “Roma Tre”

Zitieren

APA

Portaro, M., Rocchetti, I., Tuccimei, P., Galli, G., Soligo, M., Longoni, C., & Vasquez, D. (2024). The Scale Model Room Approach to Test the Performance of Airtight Membranes to Control Indoor Radon Levels and Radiation Exposure. Atmosphere, 15(10), 1260. https://doi.org/10.3390/atmos15101260

Vancouver

Portaro M, Rocchetti I, Tuccimei P, Galli G, Soligo M, Longoni C, et al. The Scale Model Room Approach to Test the Performance of Airtight Membranes to Control Indoor Radon Levels and Radiation Exposure. Atmosphere. 2024;15(10):1260. doi:10.3390/atmos15101260

BibTeX
@article{Portaro2024,
  author = {Portaro, Manuela and Rocchetti, Ilaria and Tuccimei, Paola and Galli, Gianfranco and Soligo, Michele and Longoni, Cristina and Vasquez, Dino},
  title = {The Scale Model Room Approach to Test the Performance of Airtight Membranes to Control Indoor Radon Levels and Radiation Exposure},
  journal = {Atmosphere},
  year = {2024},
  volume = {15},
  number = {10},
  pages = {1260},
  doi = {10.3390/atmos15101260}
}
Kostenlos starten →