EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements

Gabriel-Cristian Dobrei, Mircea-Claudiu Moldovan, Tiberius Dicu, Ștefan Florică, Alexandru-Iulian Lupulescu, Ancuța-Cristina Țenter, Alexandra Cucoș

Atmosphere · 26.09.2024 · 15 (10) · 1154

DOI: 10.3390/atmos15101154 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Atmosphere, online erschienen am 26.09.2024. Verfasst von Gabriel-Cristian Dobrei und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Research, Innovation and Digitization, CNCS–UEFISCDI, Smart Systems for Public Safety through Control and Mitigation of Residential Radon linked with Energy Efficiency Optimization of Buildings in Romanian Major U….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the higher susceptibility of children to ionizing radiation, it is imperative to evaluate the radon activity concentration (RAC) in educational buildings, conduct additional investigations to identify radon entry routes, and implement remedial measures to minimize exposure to this radioactive gas. In Romania, educational buildings are a category of public buildings where it is mandatory to perform RAC measurements. The present study examines data obtained from 41 Romanian educational buildings, where initial and additional radon investigations were performed. The first objective was to identify the factors influencing the variability of the RAC inside the buildings. The second objective was to emphasize the importance of short-term (a few days), continuous measurements in identifying buildings with RAC exceeding the reference level. High RAC values were associated with the classrooms located on the ground floor of the building compared to the administrative ones. The multiple linear regression led to a coefficient of determination of 0.11, the relative humidity and the amount of precipitation being the main variables with a significant impact, kept in the model, the lack of a significant association between the indoor RAC and the radon potential in the soil being obtained. Comparison of the radon long-term integrated measurements with continuous, short-term, led to the suggestion of three different scenarios for the measurement work protocol. By following the suggested modifications, it is possible to accelerate the procedure in situations where the time needed to plan renovations and radon remedial measures is shorter than the time needed to conduct integrated measurements.

Förderung

  • Ministry of Research, Innovation and Digitization, CNCS–UEFISCDI
  • Smart Systems for Public Safety through Control and Mitigation of Residential Radon linked with Energy Efficiency Optimization of Buildings in Romanian Major U…

Zitieren

APA

Dobrei, G., Moldovan, M., Dicu, T., Florică, Ș., Lupulescu, A., Țenter, A., & Cucoș, A. (2024). Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements. Atmosphere, 15(10), 1154. https://doi.org/10.3390/atmos15101154

Vancouver

Dobrei G, Moldovan M, Dicu T, Florică Ș, Lupulescu A, Țenter A, et al. Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements. Atmosphere. 2024;15(10):1154. doi:10.3390/atmos15101154

BibTeX
@article{Dobrei2024,
  author = {Dobrei, Gabriel-Cristian and Moldovan, Mircea-Claudiu and Dicu, Tiberius and Florică, Ștefan and Lupulescu, Alexandru-Iulian and Țenter, Ancuța-Cristina and Cucoș, Alexandra},
  title = {Factors Influencing Radon Variability and Measurement Protocol Optimization in Romanian Educational Buildings Using Integrated and Continuous Measurements},
  journal = {Atmosphere},
  year = {2024},
  volume = {15},
  number = {10},
  pages = {1154},
  doi = {10.3390/atmos15101154}
}
Kostenlos starten →