Kurz gefasst

Fachartikel in der Zeitschrift Atmosphere, online erschienen am 16.01.2024. Verfasst von Stefan Schumacher und 5 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air cleaners with activated carbon (AC) filters for the adsorption of gaseous pollutants are often used to improve indoor air quality. As formaldehyde is a common and health-relevant indoor air pollutant, many testing standards for air cleaners, such as GB/T 18801:2015, require the cleaning efficacy to be tested with this substance. This often persuades manufacturers to optimize the employed filters specifically for formaldehyde. However, in regions where indoor formaldehyde levels are far below the guideline values, other gaseous pollutants might be more relevant. Thus, the question arises of whether the optimization for formaldehyde can have a negative impact on the adsorption of other gases. To address this question, the clean air delivery rate (CADR) of an air cleaner was determined for different test gases with either a standard AC filter or an AC filter modified for improved formaldehyde adsorption. Although the modified AC filter performed substantially better for formaldehyde, a strong reduction in the CADR was observed for toluene and nitrogen dioxide. This is a drawback for situations in which these gases are more problematic than formaldehyde. The findings suggest using either specialized filters for different applications or blends of different adsorbants to find the best compromise for the most relevant pollutants.

Zitieren

APA

Schumacher, S., Caspari, A., Schneiderwind, U., Staack, K., Sager, U., & Asbach, C. (2024). The Drawback of Optimizing Air Cleaner Filters for the Adsorption of Formaldehyde. Atmosphere, 15(1), 109. https://doi.org/10.3390/atmos15010109

Vancouver

Schumacher S, Caspari A, Schneiderwind U, Staack K, Sager U, Asbach C. The Drawback of Optimizing Air Cleaner Filters for the Adsorption of Formaldehyde. Atmosphere. 2024;15(1):109. doi:10.3390/atmos15010109

BibTeX
@article{Schumacher2024,
  author = {Schumacher, Stefan and Caspari, Anna and Schneiderwind, Ute and Staack, Katharina and Sager, Uta and Asbach, Christof},
  title = {The Drawback of Optimizing Air Cleaner Filters for the Adsorption of Formaldehyde},
  journal = {Atmosphere},
  year = {2024},
  volume = {15},
  number = {1},
  pages = {109},
  doi = {10.3390/atmos15010109}
}