Fachartikel in der Zeitschrift Applied System Innovation, online erschienen am 09.05.2026. Verfasst von Panfeng Zhang und 7 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, 2025 Applied Basic Research Program of Material Aging Research & Development Center of China National Nuclear Corporation, Science and Technology on Reactor System Design Technology Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Data collected by sensors plays a critical role in system decision-making. Microphone arrays enable distance measurement and fault localization, which is particularly critical in the radiation environments of nuclear facilities. Acoustic localization based on microphone arrays can effectively fulfill this requirement. This study experimentally evaluates the Total Ionizing Dose (TID) effects of 60Co γ-ray radiation on commercial MEMS (micro-electro-mechanical systems) silicon microphones. Five identical microphone units were simultaneously irradiated at a dose rate of 0.0342 Gy(Si)/s while continuously monitoring operating current and spectral response. Experimental results show that the commercial MEMS silicon microphones exhibit an average TID failure threshold of 932.6 ± 62.8 Gy(Si), with a 95% confidence interval of [875.5, 989.7] Gy(Si). Three degradation/failure levels are clearly defined: channel degradation, channel failure, and full system failure. Radiation exposure causes a progressive increase in operating current (up to 6.7 times the initial value), severe spectral distortion, and ultimately complete loss of localization function. This indicated that standard commercial MEMS silicon microphones possess a certain degree of tolerance to TID radiation. Subsequently, an annealing test was performed. However, Post-irradiation annealing restored the operating current but not the acoustic performance, indicating irreversible radiation-induced damage.

Förderung

  • National Natural Science Foundation of China
  • 2025 Applied Basic Research Program of Material Aging Research & Development Center of China National Nuclear Corporation
  • Science and Technology on Reactor System Design Technology Laboratory
  • Doctoral Research Fund of University of South China

Zitieren

APA

Zhang, P., Du, X., Ma, C., Wu, Y., Li, Z., Yun, H., Wei, J., & Zheng, Z. (2026). Total Ionizing Dose Effects Investigation on the Performance of MEMS Microphone Irradiated by γ-Ray. Applied System Innovation, 9(5), 97. https://doi.org/10.3390/asi9050097

Vancouver

Zhang P, Du X, Ma C, Wu Y, Li Z, Yun H, et al. Total Ionizing Dose Effects Investigation on the Performance of MEMS Microphone Irradiated by γ-Ray. Applied System Innovation. 2026;9(5):97. doi:10.3390/asi9050097

BibTeX
@article{Zhang2026,
  author = {Zhang, Panfeng and Du, Xuecheng and Ma, Chao and Wu, Yiran and Li, Zhenya and Yun, Hao and Wei, Jiajun and Zheng, Zhirui},
  title = {Total Ionizing Dose Effects Investigation on the Performance of MEMS Microphone Irradiated by γ-Ray},
  journal = {Applied System Innovation},
  year = {2026},
  volume = {9},
  number = {5},
  pages = {97},
  doi = {10.3390/asi9050097}
}
Kostenlos starten →