Proactive Cooling Control Algorithm for Data Centers Based on LSTM-Driven Predictive Thermal Analysis

Jieying Liu, Rui Fan, Zonglin Li, Napat Harnpornchai, Jianlei Qian

Applied System Innovation · 12.01.2026 · 9 (1) · 21

DOI: 10.3390/asi9010021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied System Innovation, online erschienen am 12.01.2026. Verfasst von Jieying Liu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The conventional reactive cooling strategy, which relies on static thresholds, has become inadequate for managing dynamically changing heat loads, often resulting in energy inefficiency and increased risk of local hot spots. In this study, we develop a data center cooling optimization system that integrates distributed sensor arrays for predictive analysis. By deploying high-density temperature and humidity sensors both inside and outside server racks, a real-time, high-fidelity three-dimensional digital twin of the data center’s thermal environment is constructed. Time-series analysis combined with Long Short-Term Memory algorithms is employed to forecast temperature and humidity based on the extensive environmental data collected, achieving high predictive accuracy with a root mean square error of 0.25 and an R2 value of 0.985. Building on these predictions, a proactive cooling control strategy is formulated to dynamically adjust fan speeds and the opening degree of chilled-water valves in computer room air conditioning units, changing the cooling approach from passive to preemptive prevention of overheating. Compared with conventional proportional–integral–differential control, the developed system significantly reduces overall energy consumption and maintains all equipment within safe operating temperatures. Specifically, the framework has reduced the energy consumption of the cooling system by 37.5%, lowered the overall power usage effectiveness of the data center by 12% (1.48 to 1.30), and suppressed the cumulative hotspot duration (temperature 27 °C) by nearly 96% (from 48 to 2 h).

Zitieren

APA

Liu, J., Fan, R., Li, Z., Harnpornchai, N., & Qian, J. (2026). Proactive Cooling Control Algorithm for Data Centers Based on LSTM-Driven Predictive Thermal Analysis. Applied System Innovation, 9(1), 21. https://doi.org/10.3390/asi9010021

Vancouver

Liu J, Fan R, Li Z, Harnpornchai N, Qian J. Proactive Cooling Control Algorithm for Data Centers Based on LSTM-Driven Predictive Thermal Analysis. Applied System Innovation. 2026;9(1):21. doi:10.3390/asi9010021

BibTeX
@article{Liu2026,
  author = {Liu, Jieying and Fan, Rui and Li, Zonglin and Harnpornchai, Napat and Qian, Jianlei},
  title = {Proactive Cooling Control Algorithm for Data Centers Based on LSTM-Driven Predictive Thermal Analysis},
  journal = {Applied System Innovation},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {21},
  doi = {10.3390/asi9010021}
}
Kostenlos starten →