EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Lower Limb Activity Classification with Electromyography and Inertial Measurement Unit Sensors Using a Temporal Convolutional Neural Network on an Experimental Dataset

Mohamed A. El-Khoreby, A. Moawad, Hanady H. Issa, Shereen I. Fawaz, Mohammed I. Awad, A. Abdellatif

Applied System Innovation · 28.12.2025 · 9 (1) · 13

DOI: 10.3390/asi9010013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied System Innovation, online erschienen am 28.12.2025. Verfasst von Mohamed A. El-Khoreby und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Information Technology Industry Development Agency (ITIDA)—Information Technology Academia Collaboration (ITAC) program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate recognition of lower limb activities is essential for wearable rehabilitation systems and assistive robotics like exoskeletons and prosthetics. This study introduces SDALLE, a custom hardware data acquisition system that integrates surface electromyography sensors (EMGs) and inertial measurement sensors (IMUs) into a wireless, portable platform for locomotor monitoring. Using this system, data were collected from nine healthy subjects performing four fundamental locomotor activities: walking, jogging, stair ascent, and stair descent. The recorded signals underwent an offline structured preprocessing pipeline consisting of time-series augmentation (jittering and scaling) to increase data diversity, followed by wavelet-based denoising to suppress high-frequency noise and enhance signal quality. A temporal one-dimensional convolutional neural network (1D-TCNN) with three convolutional blocks and fully connected layers was trained on the prepared dataset to classify the four activities. Classification using IMU sensors achieved the highest performance, with accuracies ranging from 0.81 to 0.95. The gyroscope X-axis of the left Rectus Femoris achieved the best performance (0.95), while accelerometer signals also performed strongly, reaching 0.93 for the Vastus Medialis in the Y direction. In contrast, electromyography channels showed lower discriminative capability. These results demonstrate that the combination of SDALLE hardware, appropriate data preprocessing, and a temporal CNN provides an effective offline sensing and activity classification pipeline for lower limb activity recognition and offers an open-source dataset that supports further research in human activity recognition, rehabilitation, and assistive robotics.

Förderung

  • Information Technology Industry Development Agency (ITIDA)—Information Technology Academia Collaboration (ITAC) program

Zitieren

APA

El-Khoreby, M. A., Moawad, A., Issa, H. H., Fawaz, S. I., Awad, M. I., & Abdellatif, A. (2025). Lower Limb Activity Classification with Electromyography and Inertial Measurement Unit Sensors Using a Temporal Convolutional Neural Network on an Experimental Dataset. Applied System Innovation, 9(1), 13. https://doi.org/10.3390/asi9010013

Vancouver

El-Khoreby MA, Moawad A, Issa HH, Fawaz SI, Awad MI, Abdellatif A. Lower Limb Activity Classification with Electromyography and Inertial Measurement Unit Sensors Using a Temporal Convolutional Neural Network on an Experimental Dataset. Applied System Innovation. 2025;9(1):13. doi:10.3390/asi9010013

BibTeX
@article{ElKhoreby2025,
  author = {El-Khoreby, Mohamed A. and Moawad, A. and Issa, Hanady H. and Fawaz, Shereen I. and Awad, Mohammed I. and Abdellatif, A.},
  title = {Lower Limb Activity Classification with Electromyography and Inertial Measurement Unit Sensors Using a Temporal Convolutional Neural Network on an Experimental Dataset},
  journal = {Applied System Innovation},
  year = {2025},
  volume = {9},
  number = {1},
  pages = {13},
  doi = {10.3390/asi9010013}
}
Kostenlos starten →