Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework
Architecture · 23.11.2026 · 6 (4) · 223
DOI: 10.3390/architecture6040223 ↗Kurz gefasst
Fachartikel in der Zeitschrift Architecture, online erschienen am 23.11.2026. Verfasst von Abinaya J. und 1 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
India’s Green Building Rating System (GRIHA) has progressively expanded its Indoor Environmental Quality (IEQ) provisions, yet these remain based on design-stage documentation rather than empirically measured occupant priorities, particularly for warm-humid higher educational buildings. This study addresses that gap by combining regression-based importance weighting with framework-level and occupant-level Importance-Performance Analysis (IPA), drawing on post-occupancy surveys of 981 occupants across two GRIHA-certified higher educational buildings in South India (3-Star, n = 208; 4-Star, n = 773). Multiple regression identified Acoustic Comfort as the strongest predictor of perceived productivity (beta = 0.514, p < 0.001), followed by Spatial Comfort (beta = 0.198, p < 0.001); Indoor Air Quality was not a significant predictor (beta = 0.024, p = 0.298), with the model explaining 76.3% of variance (R2 = 0.763). Framework-level IPA placed Acoustic and Spatial Comfort in the under-invested quadrant (high regression beta, low GRIHA allocation), while Indoor Air Quality, which receives 54% of GRIHA’s IEQ points, fell in the over-invested quadrant (low beta, high allocation). Occupant-level IPA rated Acoustic Comfort as the most important domain and identified Spatial Comfort as the only domain in the Concentrate Here quadrant, and an independently derived Bayesian estimate of domain weights ranked Acoustic Comfort highest and Indoor Air Quality lowest, in agreement with the regression. Based on these findings, a recalibration is proposed: acoustic weighting increased from 2 to 5 points (partly mandatory), a new 3-point Spatial Comfort criterion introduced, IAQ allocation reduced from 7 to 4 points, with credit routes adapted to ventilation mode, and a voluntary 2-point post-occupancy evaluation bonus added, broadly consistent with LEED v5’s parallel shift toward occupant-experience criteria.
Zitieren
APA
J., A., & Suseelan, A. (2026). Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework. Architecture, 6(4), 223. https://doi.org/10.3390/architecture6040223
Vancouver
J. A, Suseelan A. Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework. Architecture. 2026;6(4):223. doi:10.3390/architecture6040223
BibTeX
@article{J2026,
author = {J., Abinaya and Suseelan, Anitha},
title = {Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework},
journal = {Architecture},
year = {2026},
volume = {6},
number = {4},
pages = {223},
doi = {10.3390/architecture6040223}
}
EUVIMED