EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Laser Biospeckles Analysis for Rapid Evaluation of Organic Pollutants in Water

Arti Devi, Hirofumi Kadono, Uma Maheswari Rajagopalan

AppliedPhys · 2025

DOI: 10.3390/appliedphys2010001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AppliedPhys, 2025. Verfasst von Arti Devi und 2 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Grant—in Aid for Challenging Research,.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid evaluation of water toxicity requires biological methods capable of detecting sub-lethal physiological changes without depending on chemical identification. Conventional microscopy-based bioassays are limited by low throughput and difficulties in observing small, transparent and fast-moving microorganisms. This study applies a laser-biospeckle, non-imaging microbioassay to assess the motility responses of Paramecium caudatum and Euglena gracilis exposed to two organic pollutants, trichloroacetic acid (TCAA) and acephate. Dynamic speckle patterns were recorded using a 638 nm laser diode (Thorlabs Inc., Tokyo, Japan) and a CCD camera (Gazo Co., Ltd., Tokyo, Japan) at 60 fps for 120 s. Correlation time, derived from temporal cross-correlation analysis, served as a quantitative indicator of motility. Exposure to TCAA (0.1–50 mg/L) produced strong concentration-dependent inhibition, with correlation time increasing up to 16-fold at 500× PL in P. caudatum (p < 0.01), whereas E. gracilis showed a delayed response, with significant inhibition only above 250× PL. In contrast, acephate exposure (0.036–3.6 mg/L) induced motility enhancement in both species, reflected by decreases in correlation time of up to 57% in P. caudatum and 40% in E. gracilis at 100× PL. Acute trends diminished after 24–48 h, indicating time-dependent physiological adaptation. These results demonstrate that biospeckled-derived correlation time sensitively captures both inhibitory and stimulatory behavioral responses, enabling real-time, high-throughput water toxicity screening without microscopic imaging. The method shows strong potential for integration into automated water-quality monitoring systems.

Förderung

  • Japan Society for the Promotion of Science, Grant—in Aid for Challenging Research,

Zitieren

APA

Devi, A., Kadono, H., & Rajagopalan, U. M. (2025). Laser Biospeckles Analysis for Rapid Evaluation of Organic Pollutants in Water. AppliedPhys. https://doi.org/10.3390/appliedphys2010001

Vancouver

Devi A, Kadono H, Rajagopalan UM. Laser Biospeckles Analysis for Rapid Evaluation of Organic Pollutants in Water. AppliedPhys. 2025. doi:10.3390/appliedphys2010001

BibTeX
@article{Devi2025,
  author = {Devi, Arti and Kadono, Hirofumi and Rajagopalan, Uma Maheswari},
  title = {Laser Biospeckles Analysis for Rapid Evaluation of Organic Pollutants in Water},
  journal = {AppliedPhys},
  year = {2025},
  doi = {10.3390/appliedphys2010001}
}
Kostenlos starten →