EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting

Manuel Reis Carneiro

Applied Sciences · 23.11.2026 · 16 (23) · 11592

DOI: 10.3390/app162311592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 23.11.2026. Verfasst von Manuel Reis Carneiro. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional and soft skin-contact electrodes are difficult to compare when material, interface, and physiological evidence are conflated. This article presents a methodological synthesis and proposed evaluation framework; no new experiments or participant-level data analyses are reported. For non-invasive electrocardiography (ECG), surface electromyography (EMG), and electroencephalography (EEG), it links intended-use claims to applicable tests, measurement definitions, evidence requirements, reporting, and justified conclusions. A common core and conditional modules organize electrical, mechanical, physiological, and wearer assessments. The 36-item Bioelectronic Electrode Evaluation and Reporting (BEER) checklist documents these decisions and missing evidence. A constructed ECG example illustrates the recording-time and event calculations. In that example, two hypothetical configurations each scheduled for 360 s have identical median absolute timing errors of 2 ms among matched beats, but usable scheduled-time coverage is 91.67% (330 s) and 66.67% (240 s). These calculations illustrate why matched-beat timing alone cannot establish full-period monitoring performance. Applications to two published electrode comparisons show how the framework informs the selection of textile ECG electrodes and the interpretation of channel reliability in dry multipin EEG caps. A complete retrospective BEER report for a published printed bioelectronic patch links all 36 checklist dispositions to experimental evidence, reporting gaps and claim-specific conclusions. The framework makes the grounds for supporting, narrowing, or withholding claims explicit; its usability and reproducibility require prospective evaluation.

Zitieren

APA

Carneiro, M. R. (2026). Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting. Applied Sciences, 16(23), 11592. https://doi.org/10.3390/app162311592

Vancouver

Carneiro MR. Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting. Applied Sciences. 2026;16(23):11592. doi:10.3390/app162311592

BibTeX
@article{Carneiro2026,
  author = {Carneiro, Manuel Reis},
  title = {Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {23},
  pages = {11592},
  doi = {10.3390/app162311592}
}
Kostenlos starten →