Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 18.11.2026. Verfasst von Jianfang Chen und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Anhui Electric Power Company Electric Power Science Research Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The variability of renewable generation and load demand complicates energy storage planning for islanded microgrids, particularly when siting, sizing, operating reliability, and economic performance must be considered simultaneously. This paper proposes a source-load data-driven method for siting and sizing distributed energy storage in an islanded microgrid. An improved grey wolf optimiser-gated recurrent unit (IGWO-GRU) model was developed to forecast photovoltaic output and nodal loads under normal and adverse weather conditions. The forecasts were incorporated into a multi-objective planning model that maximised islanded supply reliability and capacity-normalised discharge throughput while minimising annualised planning and operating cost. Continuous state-of-charge evolution, transitions between grid-connected and islanded operation, nodal-voltage limits, line-loading limits, upstream-grid power exchange, and priority supply to critical loads were explicitly considered. NSGA-III was directly coupled with a pandapower full-chronology AC power-flow model so that every candidate configuration was evaluated from its simulated operating performance. In the synthetic PV–BESS IEEE 33-bus case study, the 1319 h chronological assessment yielded 640 feasible configurations, including 10 non-dominated solutions. For this synthetic case and predefined candidate buses, the results illustrate a chronological planning workflow and quantify conditional trade-offs among annualised cost, islanded supply reliability, and capacity utilisation. They do not establish universal forecasting or optimisation superiority.

Förderung

  • State Grid Anhui Electric Power Company Electric Power Science Research Institute

Zitieren

APA

Chen, J., Yu, H., Zhou, T., Wang, G., Wang, Z., Su, J., Wu, Y., Sha, G., Zhou, G., & Yang, Y. (2026). Source–Load Data-Driven Multi-Objective Siting and Sizing of Distributed Energy Storage in Islanded Microgrids. Applied Sciences, 16(22), 11448. https://doi.org/10.3390/app162211448

Vancouver

Chen J, Yu H, Zhou T, Wang G, Wang Z, Su J, et al. Source–Load Data-Driven Multi-Objective Siting and Sizing of Distributed Energy Storage in Islanded Microgrids. Applied Sciences. 2026;16(22):11448. doi:10.3390/app162211448

BibTeX
@article{Chen2026,
  author = {Chen, Jianfang and Yu, Haijun and Zhou, Tao and Wang, Guansen and Wang, Zhong and Su, Jianming and Wu, Yunzhao and Sha, Guanglin and Zhou, Guangjing and Yang, Yi},
  title = {Source–Load Data-Driven Multi-Objective Siting and Sizing of Distributed Energy Storage in Islanded Microgrids},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {11448},
  doi = {10.3390/app162211448}
}
Kostenlos starten →