EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental Characterization of Laser-Generated Ultrasound Using an Er:Glass Laser and Optical Microphone

Caspar Wasle, Florian Heilemann, Rebecca Rodeck, Gerko Wende

Applied Sciences · 17.11.2026 · 16 (22) · 11376

DOI: 10.3390/app162211376 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.11.2026. Verfasst von Caspar Wasle und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates a fully contactless laser-ultrasound setup combining a compact erbium-glass (Er:glass) laser operating at an eye-safe wavelength of 1540 nm and an optical microphone. The objective is to provide a baseline experimental characterization of this configuration under controlled conditions. Experiments are conducted on aluminum plates of varying thickness in both through-transmission (forward detection) and single-sided (backward detection) measurement configurations, using laser pulse energies between 0.9 mJ and 10 mJ. Measurable ultrasonic signals are obtained across all tested conditions, with signal amplitudes exceeding the noise floor even at the lowest pulse energy. Both guided-wave components and thickness-resonance frequencies are observed, with measured resonance frequencies in reasonable agreement with theoretical expectations. Parametric studies show systematic dependencies of signal amplitude, reported in absolute sound-pressure units, on laser energy, spot size, and microphone standoff distance. The airborne radiation characteristics of the generated ultrasound are analyzed to determine suitable sensor placement for different wave components. In single-sided configurations, disturbance mechanisms including direct optical interference and air-coupled acoustic waves are identified. The use of a shielding wall with minimal air gap is shown to reduce airborne disturbance components. The results provide quantitative baseline data on the acoustic response of the Er:glass laser–microphone system and demonstrate its feasibility for compact, eye-safe, contactless ultrasonic measurements within the investigated parameter range.

Zitieren

APA

Wasle, C., Heilemann, F., Rodeck, R., & Wende, G. (2026). Experimental Characterization of Laser-Generated Ultrasound Using an Er:Glass Laser and Optical Microphone. Applied Sciences, 16(22), 11376. https://doi.org/10.3390/app162211376

Vancouver

Wasle C, Heilemann F, Rodeck R, Wende G. Experimental Characterization of Laser-Generated Ultrasound Using an Er:Glass Laser and Optical Microphone. Applied Sciences. 2026;16(22):11376. doi:10.3390/app162211376

BibTeX
@article{Wasle2026,
  author = {Wasle, Caspar and Heilemann, Florian and Rodeck, Rebecca and Wende, Gerko},
  title = {Experimental Characterization of Laser-Generated Ultrasound Using an Er:Glass Laser and Optical Microphone},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {11376},
  doi = {10.3390/app162211376}
}