Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot
Applied Sciences · 17.11.2026 · 16 (22) · 11373
DOI: 10.3390/app162211373 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.11.2026. Verfasst von Yuepeng Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Engineering Technology Research Center of Guangdong Province’s General Universities and Colleges, Projects of Shenzhen University of Information Technology.
Abstract (Originalsprache)
To isolate the low-frequency vibration of the ground-penetrating radar (GPR) payload mounted at the end of a manipulator on a tunnel diagnostic vehicle, a two degree-of-freedom (DOF) quasi-zero-stiffness (QZS) vibration isolator is proposed. It consists of two identical 1-DOF units stacked vertically and arranged orthogonally in the horizontal plane. Each unit integrates linear extension springs, a rhombus negative-stiffness mechanism, an X-shaped positive-stiffness mechanism, a guide mechanism, and an offset compensation module. A static/dynamic model is established, the key parameters are optimized by a genetic algorithm, and the critical support structures are topologically optimized with a mass reduction of more than 50%. The optimized dimensionless stiffness at the static equilibrium is 0.2204, and the onset isolation frequency is about 0.6 Hz; the displacement transmissibility is below 0.5 above 1 Hz. Under pulse excitation, the peak-to-peak acceleration and displacement are reduced to approximately 6.2% and 28.5% of those of a linear isolator, respectively. Under 1.5 Hz harmonic excitation, the steady-state absolute acceleration and displacement amplitudes are reduced by about 41% and 48%, respectively, while the dynamic deflection increases. In vehicle–arm co-simulations under three pulse cases, the peak-to-peak displacement and acceleration are reduced by 48.59–74.38% and 84.73–93.44%, respectively. Under D-grade random road excitation, the peak-to-peak acceleration and acceleration RMS are reduced by 53.34% and 77.25%, respectively; the peak-to-peak displacement is reduced by 12.63%, whereas the peak absolute displacement and displacement RMS increase slightly by 1.21% and 3.62%. The maximum dynamic displacement remains within the designed ±50 mm stroke. The results show that the proposed isolator achieves pronounced low-frequency acceleration suppression at the cost of a small displacement increase, and the offset compensation module maintains the QZS operating point under ±90° tilting. These findings provide a passive isolation solution for manipulator-mounted precision equipment.
Förderung
- National Natural Science Foundation of China
- Engineering Technology Research Center of Guangdong Province’s General Universities and Colleges
- Projects of Shenzhen University of Information Technology
- Shenzhen Science and Technology Program
Zitieren
APA
Zhang, Y., Wang, S., Cao, G., Zhu, X., Gao, B., & Xia, L. (2026). Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot. Applied Sciences, 16(22), 11373. https://doi.org/10.3390/app162211373
Vancouver
Zhang Y, Wang S, Cao G, Zhu X, Gao B, Xia L. Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot. Applied Sciences. 2026;16(22):11373. doi:10.3390/app162211373
BibTeX
@article{Zhang2026,
author = {Zhang, Yuepeng and Wang, Shaohong and Cao, Guangzhong and Zhu, Xueli and Gao, Bo and Xia, Linzhong},
title = {Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {22},
pages = {11373},
doi = {10.3390/app162211373}
}