EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot

Yuepeng Zhang, Shaohong Wang, Guangzhong Cao, Xueli Zhu, Bo Gao, Linzhong Xia

Applied Sciences · 17.11.2026 · 16 (22) · 11373

DOI: 10.3390/app162211373 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.11.2026. Verfasst von Yuepeng Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Engineering Technology Research Center of Guangdong Province’s General Universities and Colleges, Projects of Shenzhen University of Information Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To isolate the low-frequency vibration of the ground-penetrating radar (GPR) payload mounted at the end of a manipulator on a tunnel diagnostic vehicle, a two degree-of-freedom (DOF) quasi-zero-stiffness (QZS) vibration isolator is proposed. It consists of two identical 1-DOF units stacked vertically and arranged orthogonally in the horizontal plane. Each unit integrates linear extension springs, a rhombus negative-stiffness mechanism, an X-shaped positive-stiffness mechanism, a guide mechanism, and an offset compensation module. A static/dynamic model is established, the key parameters are optimized by a genetic algorithm, and the critical support structures are topologically optimized with a mass reduction of more than 50%. The optimized dimensionless stiffness at the static equilibrium is 0.2204, and the onset isolation frequency is about 0.6 Hz; the displacement transmissibility is below 0.5 above 1 Hz. Under pulse excitation, the peak-to-peak acceleration and displacement are reduced to approximately 6.2% and 28.5% of those of a linear isolator, respectively. Under 1.5 Hz harmonic excitation, the steady-state absolute acceleration and displacement amplitudes are reduced by about 41% and 48%, respectively, while the dynamic deflection increases. In vehicle–arm co-simulations under three pulse cases, the peak-to-peak displacement and acceleration are reduced by 48.59–74.38% and 84.73–93.44%, respectively. Under D-grade random road excitation, the peak-to-peak acceleration and acceleration RMS are reduced by 53.34% and 77.25%, respectively; the peak-to-peak displacement is reduced by 12.63%, whereas the peak absolute displacement and displacement RMS increase slightly by 1.21% and 3.62%. The maximum dynamic displacement remains within the designed ±50 mm stroke. The results show that the proposed isolator achieves pronounced low-frequency acceleration suppression at the cost of a small displacement increase, and the offset compensation module maintains the QZS operating point under ±90° tilting. These findings provide a passive isolation solution for manipulator-mounted precision equipment.

Förderung

  • National Natural Science Foundation of China
  • Engineering Technology Research Center of Guangdong Province’s General Universities and Colleges
  • Projects of Shenzhen University of Information Technology
  • Shenzhen Science and Technology Program

Zitieren

APA

Zhang, Y., Wang, S., Cao, G., Zhu, X., Gao, B., & Xia, L. (2026). Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot. Applied Sciences, 16(22), 11373. https://doi.org/10.3390/app162211373

Vancouver

Zhang Y, Wang S, Cao G, Zhu X, Gao B, Xia L. Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot. Applied Sciences. 2026;16(22):11373. doi:10.3390/app162211373

BibTeX
@article{Zhang2026,
  author = {Zhang, Yuepeng and Wang, Shaohong and Cao, Guangzhong and Zhu, Xueli and Gao, Bo and Xia, Linzhong},
  title = {Research on Quasi-Zero-Stiffness Vibration Isolator for the End-Effector of a Tunnel Inspection Robot},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {11373},
  doi = {10.3390/app162211373}
}
Kostenlos starten →