EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics

Cong Wu, Wantao Xu, Xiaoqian Liu, Hongyu Ge, Hao Yang, Fuqiang Tian

Applied Sciences · 13.11.2026 · 16 (22) · 11272

DOI: 10.3390/app162211272 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 13.11.2026. Verfasst von Cong Wu und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Switching operations of onboard vacuum circuit breakers (VCBs) during electrical phase separation can induce transient overvoltages in high-speed electric multiple units (EMUs). This study develops a PSCAD/EMTDC model of the CR400AF high-voltage system, incorporating a combined Mayr–Cassie dynamic arc model for opening and a time-varying resistance model for closing. The voltage responses at the pantograph terminal (P1), VCB output terminal (P2), and traction transformer high-voltage input (P3) are investigated, together with the effects of switching phase and contact movement speed. Under representative switching conditions, the simulated voltage peaks at P1, P2, and P3 were 341.96, 63.95, and 38.90 kV during closing at 90∘, respectively, compared with 208.79, 77.08, and 54.71 kV during opening at 0∘. During closing, the maximum voltage rate of rise at P1 reached 1827.15 kV/μs. Phase scans show higher closing overvoltages near 90∘ and 270∘, but higher opening overvoltages near 0∘ and 180∘. Over a contact-speed range of 0.5–2.0 m/s, the largest closing and opening peaks occur at 0.6 and 1.8 m/s, respectively. A parameter perturbation analysis shows that simultaneous variations of ±10% in the selected flexible-conductor RLC parameters result in peak-voltage deviations below 5% under the representative opening and closing conditions. A nine-case multifactor study of closing phase, contact speed, and distributed parameters further identifies peak voltages ranging from 229.09 to 341.96 kV within the investigated combinations. These results characterize operation-dependent voltage distributions and parameter effects, supporting the assessment of transient voltage stresses in onboard high-voltage equipment.

Zitieren

APA

Wu, C., Xu, W., Liu, X., Ge, H., Yang, H., & Tian, F. (2026). Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics. Applied Sciences, 16(22), 11272. https://doi.org/10.3390/app162211272

Vancouver

Wu C, Xu W, Liu X, Ge H, Yang H, Tian F. Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics. Applied Sciences. 2026;16(22):11272. doi:10.3390/app162211272

BibTeX
@article{Wu2026,
  author = {Wu, Cong and Xu, Wantao and Liu, Xiaoqian and Ge, Hongyu and Yang, Hao and Tian, Fuqiang},
  title = {Switching Overvoltages in High-Speed EMUs Considering VCB Arc Characteristics},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {11272},
  doi = {10.3390/app162211272}
}
Kostenlos starten →