RSAS-FxLMS: A Robust Active Noise Control Method for Vibrator Operation Noise in Precast Beam Plants
Applied Sciences · 11.11.2026 · 16 (22) · 11165
DOI: 10.3390/app162211165 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 11.11.2026. Verfasst von Ting Zha und 5 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Open Foundation of Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Doctoral Start-up Foundation of Hubei University of Technology, China.
Abstract (Originalsprache)
To improve active noise control of 120–180 Hz vibrator noise in precast beam plants under strong impulsive disturbances, this paper proposes a robust scaled adaptive step-size filtered-x least mean square (RSAS-FxLMS) algorithm. The conventional scaled adaptive step-size filtered-x least mean square (SAS-FxLMS) algorithm is prone to weight instability and divergence under strong impacts. The proposed method embeds a dual stabilization mechanism: an adaptive divergence detector based on short-term error energy triggers weight vector reset and step-size rollback, while a norm constraint is imposed on the weight vector after each iteration. The signal preprocessing chain is optimized using a high-order bandpass filter and an offline secondary path model identified with swept-frequency excitation and a weighted-error criterion. Simulations using field-measured vibrator noise show that the proposed algorithm achieves a noise reduction of 33.3 dB at 150 Hz, which is 27.63 dB higher than that of the conventional SAS-FxLMS algorithm, and an average noise reduction of 29.10 dB across the 120–180 Hz target band, which is 20.91 dB higher than that of the conventional SAS-FxLMS algorithm. Under continuous high-intensity impacts, the weight vector remains bounded, and the error signal re-converges quickly without divergence. The algorithm also achieves faster convergence in more than 80% of the convergence period. These results demonstrate that the proposed method effectively suppresses strong impulsive narrowband vibrator noise with high reduction depth and strong robustness. The evaluation uses field-recorded vibrator noise as the input, whereas the primary and secondary acoustic paths are modelled; it is therefore an open-loop, offline assessment and does not constitute a closed-loop or real-time experimental validation of an ANC system, so that the results provide an algorithmic reference for industrial ANC rather than a demonstration of field performance.
Förderung
- National Natural Science Foundation of China
- Open Foundation of Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System
- Doctoral Start-up Foundation of Hubei University of Technology, China
Zitieren
APA
Zha, T., Gu, R., Song, H., Wu, M., Ding, G., & Yang, J. (2026). RSAS-FxLMS: A Robust Active Noise Control Method for Vibrator Operation Noise in Precast Beam Plants. Applied Sciences, 16(22), 11165. https://doi.org/10.3390/app162211165
Vancouver
Zha T, Gu R, Song H, Wu M, Ding G, Yang J. RSAS-FxLMS: A Robust Active Noise Control Method for Vibrator Operation Noise in Precast Beam Plants. Applied Sciences. 2026;16(22):11165. doi:10.3390/app162211165
BibTeX
@article{Zha2026,
author = {Zha, Ting and Gu, Ran and Song, Haina and Wu, Minghu and Ding, Guangang and Yang, Jianbo},
title = {RSAS-FxLMS: A Robust Active Noise Control Method for Vibrator Operation Noise in Precast Beam Plants},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {22},
pages = {11165},
doi = {10.3390/app162211165}
}