EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simulation-Based Functional Assessment of a Single Commercial AI-Assisted ECG Workflow: A Pre-Implementation Proof-of-Concept Study

Leonel Vasquez-Cevallos, Ricardo Grunauer-Robalino, Susana Muñoz-Hernández, Ángel Herranz-Nieva, Pedro A. Salazar-Carballo, Paul E. D. Soto-Rodriguez

Applied Sciences · 20.08.2026 · 16 (16) · 8282

DOI: 10.3390/app16168282 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 20.08.2026. Verfasst von Leonel Vasquez-Cevallos und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commercial artificial intelligence (AI)-assisted electrocardiography systems require local assessment of the acquisition-to-review pathway before patient-facing use. We conducted a single-site, simulation-based functional assessment of one commercial 12-lead ECG configuration. A physiological signal simulator, ECG acquisition unit, AI-assisted review platform, multiparameter monitor, and central monitoring system were used to examine 13 predefined rhythm and conduction categories, alarm behavior, local export pathways, a representative five-lead signal-display subset, and formative expert feedback. Expected category-level functional agreement was observed in 12 of 13 predefined categories. In the retained record, the discordant asystole scenario was categorized as lead-off/electrode disconnection, identifying a signal-integrity boundary that requires verification of electrodes, leads, cables, waveforms, and context before clinician adjudication. Signal-to-noise ratio and root-mean-square error values from 90 derived windows in five leads were reported descriptively. These findings cannot be generalized to the seven unmeasured diagnostic leads or to complete 12-lead signal fidelity. Local PDF, HL7 v2.x, DICOM, and platform synchronization were demonstrated without independent conformance or semantic-integrity testing. Formative input from six purposively selected experts comprised 30 ordinal ratings (median 5; observed range 4–5) and qualitative comments. These data do not constitute usability or educational-effectiveness validation. The study provides bounded functional evidence for the tested configuration and identifies requirements for prospective technical, human-factors, multivendor, and patient-level validation before clinical deployment.

Zitieren

APA

Vasquez-Cevallos, L., Grunauer-Robalino, R., Muñoz-Hernández, S., Herranz-Nieva, Á., Salazar-Carballo, P. A., & Soto-Rodriguez, P. E. D. (2026). Simulation-Based Functional Assessment of a Single Commercial AI-Assisted ECG Workflow: A Pre-Implementation Proof-of-Concept Study. Applied Sciences, 16(16), 8282. https://doi.org/10.3390/app16168282

Vancouver

Vasquez-Cevallos L, Grunauer-Robalino R, Muñoz-Hernández S, Herranz-Nieva Á, Salazar-Carballo PA, Soto-Rodriguez PED. Simulation-Based Functional Assessment of a Single Commercial AI-Assisted ECG Workflow: A Pre-Implementation Proof-of-Concept Study. Applied Sciences. 2026;16(16):8282. doi:10.3390/app16168282

BibTeX
@article{VasquezCevallos2026,
  author = {Vasquez-Cevallos, Leonel and Grunauer-Robalino, Ricardo and Muñoz-Hernández, Susana and Herranz-Nieva, Ángel and Salazar-Carballo, Pedro A. and Soto-Rodriguez, Paul E. D.},
  title = {Simulation-Based Functional Assessment of a Single Commercial AI-Assisted ECG Workflow: A Pre-Implementation Proof-of-Concept Study},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {16},
  pages = {8282},
  doi = {10.3390/app16168282}
}
Kostenlos starten →