EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Temperature Evolution in Liquid-Nitrogen Biobanks

Zhichun Xiong, Xiangyi Liu, Tianyu Zhu, Lifang Yao, Zhencan Yang, Zhongli Zhang, Xinqing Xiao

Applied Sciences · 03.08.2026 · 16 (15) · 7700

DOI: 10.3390/app16157700 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 03.08.2026. Verfasst von Zhichun Xiong und 6 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Institute of Measurement and Testing Technology Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid-nitrogen biobanks require stable and spatially uniform vapor-phase temperatures for long-term biological-sample storage. Transient computational fluid dynamics models were developed for automated and non-automated configurations under empty-, half-, and full-load conditions. Loading was represented using different porosity settings for homogenized storage regions, and transient temperature evolution and monitoring-point temperature uniformity were evaluated. In the automated biobank, the final monitoring-point average temperature increased from −187.90 °C under an empty load to −183.21 °C under a full load, while the final monitoring-point temperature difference increased from 10.67 °C to 13.70 °C. In the non-automated biobank, the corresponding average temperature increased from −169.65 °C to −165.38 °C, and the temperature difference increased from 7.81 °C to 10.25 °C. In both configurations, the warmest monitoring locations were more responsive to loading than the coldest locations, indicating increased spatial non-uniformity. Under their respective modeled conditions, the automated configuration reached lower monitoring-point average temperatures but exhibited larger temperature differences, whereas the non-automated configuration showed higher average temperatures but smaller differences. Because the models differed in scale, internal arrangement, thermal boundaries, and monitoring layout, the cross-configuration comparison is descriptive rather than normalized. The results provide a model-based basis for structural screening, loading management, and functional temperature-monitoring strategies.

Förderung

  • Shanghai Institute of Measurement and Testing Technology Co., Ltd.

Zitieren

APA

Xiong, Z., Liu, X., Zhu, T., Yao, L., Yang, Z., Zhang, Z., & Xiao, X. (2026). Temperature Evolution in Liquid-Nitrogen Biobanks. Applied Sciences, 16(15), 7700. https://doi.org/10.3390/app16157700

Vancouver

Xiong Z, Liu X, Zhu T, Yao L, Yang Z, Zhang Z, et al. Temperature Evolution in Liquid-Nitrogen Biobanks. Applied Sciences. 2026;16(15):7700. doi:10.3390/app16157700

BibTeX
@article{Xiong2026,
  author = {Xiong, Zhichun and Liu, Xiangyi and Zhu, Tianyu and Yao, Lifang and Yang, Zhencan and Zhang, Zhongli and Xiao, Xinqing},
  title = {Temperature Evolution in Liquid-Nitrogen Biobanks},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {7700},
  doi = {10.3390/app16157700}
}
Kostenlos starten →