EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Weak Molecular Signal Detection Mechanism Based on Cavity Plasmon

Geng-Hao Chen, Ye-Qi Zhang

Applied Sciences · 28.07.2026 · 16 (15) · 7494

DOI: 10.3390/app16157494 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 28.07.2026. Verfasst von Geng-Hao Chen und 1 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical interrogation of weak infrared molecular signatures from hazardous small molecules is important for environmental monitoring and industrial safety. However, these weak molecular responses are often difficult to distinguish using conventional far-field spectroscopy. Here, we theoretically investigate an Ag metal–insulator–metal (MIM) nanocavity as a cavity-length-engineered plasmonic platform for molecular resonance-plasmon coupling. The molecular response is incorporated through an effective-medium dielectric model for a surface-confined molecular population within the 1 nm nanogap. By tuning the cavity length, the bare cavity plasmon resonance can be matched to a selected infrared-active molecular resonance, converting weak molecular absorption responses into a finite-contrast spectral splitting in the simulated spectrum. SO2, COCl2, and H2O are first investigated as representative systems, with optimized cavity lengths of 545, 404, and 190 nm, respectively. Using a unified 5% normalized dip-depth criterion, we identify the onset of spectral splitting and obtain local threshold molecular number densities of 4.47 × 1024, 1.48 × 1025, and 1.84 × 1026 m−3, respectively. The same cavity-matching and threshold-evaluation procedure is further applied to NO2, NH3, PH3, HF, HCN, and H2S. These results provide a comparative theoretical framework for molecule-specific cavity design in MIM nanocavities.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, G., & Zhang, Y. (2026). Weak Molecular Signal Detection Mechanism Based on Cavity Plasmon. Applied Sciences, 16(15), 7494. https://doi.org/10.3390/app16157494

Vancouver

Chen G, Zhang Y. Weak Molecular Signal Detection Mechanism Based on Cavity Plasmon. Applied Sciences. 2026;16(15):7494. doi:10.3390/app16157494

BibTeX
@article{Chen2026,
  author = {Chen, Geng-Hao and Zhang, Ye-Qi},
  title = {Weak Molecular Signal Detection Mechanism Based on Cavity Plasmon},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {15},
  pages = {7494},
  doi = {10.3390/app16157494}
}
Kostenlos starten →