Evaluating Envelope, Heating System and Thermal-Mass Retrofits for Indoor Air Temperature Control and Energy Saving in a UK Residential Building
Applied Sciences · 25.07.2026 · 16 (15) · 7449
DOI: 10.3390/app16157449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 25.07.2026. Verfasst von Carmen Ambrosio und 3 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Residential buildings are central to decarbonisation because existing dwellings combine long service lives, high heating demand and heterogeneous constraints for retrofitting. This study investigates some retrofit strategies for a terraced house in Oxford, UK, to achieve the winter indoor air temperature set-point while reducing energy use, costs and CO2 emissions. A calibrated dynamic simulation model was developed from on-site inspections, monitored temperatures, occupant schedules and energy-bill data. The analysis compares baseline configuration with scenarios including radiator power upgrading, envelope insulation, increased internal thermal mass and replacement of the condensing boiler with a high-temperature ground-source heat pump (GSHP). The results show that radiator upgrading enables the most critical rooms to reach the 20 °C set-point, while envelope insulation reduces heating energy and costs. Increased thermal mass improves night-time temperature stability, although its effect on annual energy demand is limited. The GSHP provides the largest primary energy reduction, lowering operational primary energy by 66.3% compared to the reference case and by 70.4% when combined with envelope and thermal-mass measures. Operational CO2 emissions are reduced by 35.0–84.3%. The study highlights the need to evaluate the capacity of heat emitters, building envelope performance, thermal inertia and heat generator efficiency within a dynamic framework.
Zitieren
APA
Ambrosio, C., D’Agostino, D., Minelli, F., & Minichiello, F. (2026). Evaluating Envelope, Heating System and Thermal-Mass Retrofits for Indoor Air Temperature Control and Energy Saving in a UK Residential Building. Applied Sciences, 16(15), 7449. https://doi.org/10.3390/app16157449
Vancouver
Ambrosio C, D’Agostino D, Minelli F, Minichiello F. Evaluating Envelope, Heating System and Thermal-Mass Retrofits for Indoor Air Temperature Control and Energy Saving in a UK Residential Building. Applied Sciences. 2026;16(15):7449. doi:10.3390/app16157449
BibTeX
@article{Ambrosio2026,
author = {Ambrosio, Carmen and D’Agostino, Diana and Minelli, Federico and Minichiello, Francesco},
title = {Evaluating Envelope, Heating System and Thermal-Mass Retrofits for Indoor Air Temperature Control and Energy Saving in a UK Residential Building},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {15},
pages = {7449},
doi = {10.3390/app16157449}
}
EUVIMED