Validation of a Low-Cost Accelerometry Device for Cycle-Based Biomechanical Analysis of Deep-Water Running
Applied Sciences · 26.06.2026 · 16 (13) · 6404
DOI: 10.3390/app16136404 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 26.06.2026. Verfasst von Caroline C. B. Souza und 10 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordination for the Improvement of Higher Education Personnel, Centre of Research, Education, Innovation and Intervention in Sport.
Abstract (Originalsprache)
Hydrotherapy is widely used in rehabilitation because it reduces mechanical loading while preserving neuromuscular and cardiovascular stimulation. However, the biomechanical characterization of deep-water running remains limited, particularly when using accessible wearable systems for cycle-based movement analysis. This study aimed to evaluate the concurrent validity and agreement of a low-cost accelerometry device for cycle-based analysis of deep-water running, using a commercial accelerometry system as the reference measurement system. Twenty-one healthy participants performed a 25 m deep-water running task with simultaneous data acquisition from mechanically coupled sensors to ensure alignment. A total of 75 synchronized cycles were processed using a standardized pipeline that included filtering, synchronization, cycle detection, and parameter extraction. Statistical analysis was conducted using the Wilcoxon signed-rank test, intraclass correlation coefficient, Spearman’s correlation, Bland–Altman analysis, and error metrics. The results showed good agreement for temporal and volumetric variables, including cycle duration (ICC = 0.84), cumulative acceleration (ICC = 0.82), and area under the curve (ICC = 0.68). However, lower agreement and systematic bias were observed for intensity-related variables, particularly RMS and peak acceleration, despite more than 92% of cycles falling within the 95% limits of agreement (LoA). These findings suggest that the proposed device provides acceptable agreement for temporal and volumetric variables during deep-water running and may represent a low-cost alternative for movement monitoring in aquatic environments. However, intensity-related variables should be interpreted with caution due to the systematic differences observed between systems.
Förderung
- Coordination for the Improvement of Higher Education Personnel
- Centre of Research, Education, Innovation and Intervention in Sport
Zitieren
APA
Souza, C. C. B., Parolini, F., Goethel, M. F., Robalino, J., Siqueira, G. R. D., Silva, A. L. P. C., Rodrigues, M. V. B., Vilas-Boas, J. P., Correia, M. V., Rodrigues, M. A. B., & Ferreira, A. P. D. L. (2026). Validation of a Low-Cost Accelerometry Device for Cycle-Based Biomechanical Analysis of Deep-Water Running. Applied Sciences, 16(13), 6404. https://doi.org/10.3390/app16136404
Vancouver
Souza CCB, Parolini F, Goethel MF, Robalino J, Siqueira GRD, Silva ALPC, et al. Validation of a Low-Cost Accelerometry Device for Cycle-Based Biomechanical Analysis of Deep-Water Running. Applied Sciences. 2026;16(13):6404. doi:10.3390/app16136404
BibTeX
@article{Souza2026,
author = {Souza, Caroline C. B. and Parolini, Franciele and Goethel, Márcio Fagundes and Robalino, Johan and Siqueira, Gisela Rocha de and Silva, Alysson L. P. C. and Rodrigues, Marcus Vinícius B. and Vilas-Boas, João Paulo and Correia, Miguel Velhote and Rodrigues, Marco Aurélio Benedetti and Ferreira, Ana Paula de Lima},
title = {Validation of a Low-Cost Accelerometry Device for Cycle-Based Biomechanical Analysis of Deep-Water Running},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {13},
pages = {6404},
doi = {10.3390/app16136404}
}
EUVIMED