EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wind-Induced Vibration Analysis of a Tower with an Attached Vent Stack Using Fluid–Structure Interaction Modeling

Puzhen Wang, Jinliang Tao, Bingjun Gao

Applied Sciences · 16.06.2026 · 16 (12) · 6090

DOI: 10.3390/app16126090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.06.2026. Verfasst von Puzhen Wang und 2 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The tower with an attached vent stack is a special arrangement in chemical tower structures. Flow-induced vibration of this configuration directly affects the safe operation and structural fatigue life of the equipment. This paper investigates the vortex-induced vibration (VIV) characteristics of a two-cylinder system consisting of a tower and its attached vent stack. Through fluid–structure interaction (FSI) simulations of two unequally sized cylinders in a bundled arrangement, the vibration responses under first and second-mode critical wind speeds with a flow direction of 0° are analyzed. The analysis examines lift and drag coefficients, vibration displacements, and wake flow evolution to reveal the vibration response pattern under multi-parameter coupling. When the lift forces obtained from FSI are applied in a static calculation, the static results for both the first and second-mode critical wind speeds are approximately 250% larger than the FSI results, indicating a significant discrepancy. Further analysis shows that in the FSI simulations, a notable phase difference exists between the fluid excitation and the structural response, causing the lift force to do negative work during part of the vibration cycle, thereby limiting the net energy input. Under the second-mode critical wind speed, the lift distribution along the tower height is significantly non-uniform. The conventional static calculation method neglects both the phase difference and the non-uniform lift distribution along the height, leading to overly conservative predictions.

Zitieren

APA

Wang, P., Tao, J., & Gao, B. (2026). Wind-Induced Vibration Analysis of a Tower with an Attached Vent Stack Using Fluid–Structure Interaction Modeling. Applied Sciences, 16(12), 6090. https://doi.org/10.3390/app16126090

Vancouver

Wang P, Tao J, Gao B. Wind-Induced Vibration Analysis of a Tower with an Attached Vent Stack Using Fluid–Structure Interaction Modeling. Applied Sciences. 2026;16(12):6090. doi:10.3390/app16126090

BibTeX
@article{Wang2026,
  author = {Wang, Puzhen and Tao, Jinliang and Gao, Bingjun},
  title = {Wind-Induced Vibration Analysis of a Tower with an Attached Vent Stack Using Fluid–Structure Interaction Modeling},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {6090},
  doi = {10.3390/app16126090}
}
Kostenlos starten →