Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis

Alejandro Alda-Blanco, Juan José Salinero, Sergio Rodríguez-Barbero, Fernando Valero, Fernando González-Mohíno

Applied Sciences · 02.06.2026 · 16 (11) · 5526

DOI: 10.3390/app16115526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 02.06.2026. Verfasst von Alejandro Alda-Blanco und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study evaluated the reliability and reproducibility of biomechanical variables from a foot-mounted inertial measurement unit (IMU; Stryd®) and a trunk-mounted triaxial accelerometer (TTA; RunEASI®) during treadmill running.

Methods

Thirteen trained male runners (age: 27.6 ± 8.2 years; body mass: 64.4 ± 6.1 kg; height: 174.2 ± 6.4 cm) completed four treadmill sessions separated by seven days, each with four 5-min trials at 13 km·h−1. Reliability and reproducibility were assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), smallest worthwhile change (SWC) and coefficient of variation (CV).

Results

Both devices showed excellent intra-session reliability (ICC ≥ 0.90). Inter-session reproducibility was high for the IMU in running power, step frequency, and ground contact time (ICC = 0.906–0.992; CV = 0.31–1.50%); the TTA showed excellent reproducibility for the spatiotemporal variables—step frequency, ground contact time, and flight ratio (ICC = 0.931–0.956), whereas impact-related variables showed only good reproducibility (ICC = 0.823–0.871; CV up to 7.76%). Mean step frequency values were similar between devices, but trial-to-trial agreement was limited (r = 0.447; R2 = 0.20; Bland–Altman bias = 0.70 steps·min−1, LoA: −15.08 to 16.47), and ground contact time showed systematic discrepancies, with the TTA underestimating values (bias = 16.86 ms, LoA: −45.64 to 11.92).

Conclusions

Both sensors provide consistent measurements within their own systems; however, differences in sensing location produce different absolute values, so they should not be used interchangeably and interpretation must remain device-specific.

Zitieren

APA

Alda-Blanco, A., Salinero, J. J., Rodríguez-Barbero, S., Valero, F., & González-Mohíno, F. (2026). Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis. Applied Sciences, 16(11), 5526. https://doi.org/10.3390/app16115526

Vancouver

Alda-Blanco A, Salinero JJ, Rodríguez-Barbero S, Valero F, González-Mohíno F. Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis. Applied Sciences. 2026;16(11):5526. doi:10.3390/app16115526

BibTeX
@article{AldaBlanco2026,
  author = {Alda-Blanco, Alejandro and Salinero, Juan José and Rodríguez-Barbero, Sergio and Valero, Fernando and González-Mohíno, Fernando},
  title = {Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {5526},
  doi = {10.3390/app16115526}
}
Kostenlos starten →