Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis
Applied Sciences · 02.06.2026 · 16 (11) · 5526
DOI: 10.3390/app16115526 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 02.06.2026. Verfasst von Alejandro Alda-Blanco und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
This study evaluated the reliability and reproducibility of biomechanical variables from a foot-mounted inertial measurement unit (IMU; Stryd®) and a trunk-mounted triaxial accelerometer (TTA; RunEASI®) during treadmill running.
Methods
Thirteen trained male runners (age: 27.6 ± 8.2 years; body mass: 64.4 ± 6.1 kg; height: 174.2 ± 6.4 cm) completed four treadmill sessions separated by seven days, each with four 5-min trials at 13 km·h−1. Reliability and reproducibility were assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), smallest worthwhile change (SWC) and coefficient of variation (CV).
Results
Both devices showed excellent intra-session reliability (ICC ≥ 0.90). Inter-session reproducibility was high for the IMU in running power, step frequency, and ground contact time (ICC = 0.906–0.992; CV = 0.31–1.50%); the TTA showed excellent reproducibility for the spatiotemporal variables—step frequency, ground contact time, and flight ratio (ICC = 0.931–0.956), whereas impact-related variables showed only good reproducibility (ICC = 0.823–0.871; CV up to 7.76%). Mean step frequency values were similar between devices, but trial-to-trial agreement was limited (r = 0.447; R2 = 0.20; Bland–Altman bias = 0.70 steps·min−1, LoA: −15.08 to 16.47), and ground contact time showed systematic discrepancies, with the TTA underestimating values (bias = 16.86 ms, LoA: −45.64 to 11.92).
Conclusions
Both sensors provide consistent measurements within their own systems; however, differences in sensing location produce different absolute values, so they should not be used interchangeably and interpretation must remain device-specific.
Zitieren
APA
Alda-Blanco, A., Salinero, J. J., Rodríguez-Barbero, S., Valero, F., & González-Mohíno, F. (2026). Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis. Applied Sciences, 16(11), 5526. https://doi.org/10.3390/app16115526
Vancouver
Alda-Blanco A, Salinero JJ, Rodríguez-Barbero S, Valero F, González-Mohíno F. Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis. Applied Sciences. 2026;16(11):5526. doi:10.3390/app16115526
BibTeX
@article{AldaBlanco2026,
author = {Alda-Blanco, Alejandro and Salinero, Juan José and Rodríguez-Barbero, Sergio and Valero, Fernando and González-Mohíno, Fernando},
title = {Comparison Between Wearable Devices for Assessing Running Biomechanics: A Reliability and Reproducibility Analysis},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {11},
pages = {5526},
doi = {10.3390/app16115526}
}
EUVIMED