Interpretable Machine Learning Distinguishes Correct from Incorrect Rehabilitation Movement with Fewer Wearable Sensors
Applied Sciences · 07.05.2026 · 16 (10) · 4592
DOI: 10.3390/app16104592 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 07.05.2026. Verfasst von Georgios Bouchouras und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Wearable systems for rehabilitation monitoring often rely on complex sensor configurations and produce outputs that are difficult to interpret. This limits their practical use. This study investigates whether movement quality assessment can be achieved accurately and transparently using a reduced set of signals, meaning fewer body segment inertial measurement units and therefore smaller task-specific feature tables. Using wearable sensor data from lower-limb rehabilitation tasks performed under correct and intentionally erroneous conditions, we extracted a small set of rotation-based features and evaluated them within a supervised machine learning framework. The results show that these features can reliably distinguish correct from incorrect movement, with classification accuracy around 0.70, while preserving clear biomechanical interpretation. Reduced sensor configurations retained, and in some cases improved, performance, with balanced accuracy reaching 0.947 and 0.917 in the examined tasks. A proof-of-concept real-time formulation further showed that movement deviations can be detected early within repetitions, while limiting false feedback on correct executions to approximately 9%. Overall, the findings show that movement quality assessment can be achieved with minimal sensing, while also supporting early error detection and practical feedback. These properties are relevant to wearable rehabilitation systems, including internet of things applications that depend on efficient sensing, interpretable analysis, and timely feedback.
Zitieren
APA
Bouchouras, G., Sofianidis, G., Kontaxakis, E., & Kotis, K. (2026). Interpretable Machine Learning Distinguishes Correct from Incorrect Rehabilitation Movement with Fewer Wearable Sensors. Applied Sciences, 16(10), 4592. https://doi.org/10.3390/app16104592
Vancouver
Bouchouras G, Sofianidis G, Kontaxakis E, Kotis K. Interpretable Machine Learning Distinguishes Correct from Incorrect Rehabilitation Movement with Fewer Wearable Sensors. Applied Sciences. 2026;16(10):4592. doi:10.3390/app16104592
BibTeX
@article{Bouchouras2026,
author = {Bouchouras, Georgios and Sofianidis, Georgios and Kontaxakis, Evangelos and Kotis, Konstantinos},
title = {Interpretable Machine Learning Distinguishes Correct from Incorrect Rehabilitation Movement with Fewer Wearable Sensors},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {10},
pages = {4592},
doi = {10.3390/app16104592}
}
EUVIMED